Hillyard TRIDENT FMD20 Manual De Uso Y Mantenimiento página 19

Monocepillos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
THE APPLIANCE DOES NOT SWITCH ON
INSUFFICIENT DETERGENT SOLUTION
ON THE PAD HOLDER
POSSIBLE CAUSE
The power cable extension is not connected
to the mains socket.
The power cable extension is not connected
to the appliance's power cable.
The electrical specifications of the appliance
should
correspond
to
the
specifications of the power supply network.
Extension cable damaged.
Overheating of the brush head motor.
The amount of detergent in the solution tank
is insufficient for the work that needs doing.
TROUBLESHOOTING
ELECTRICAL DIAGRAM
19
19
19
SOLUTION
Check that the plug on the extension cable
has been inserted into the mains supply
socket.
Check that the plug on the cable of the
appliance has been inserted into the socket
on the extension cable.
Make sure that the electrical specifications
of the appliance correspond to the electrical
electrical
specifications of the power supply network,
check the technical information on the serial
number plate.
Check the extension cable is not damaged,
and if it is, replace it.
Make sure that the thermal breaker on the
back of the handlebar has not tripped. If it
has, wait a few minutes until it has cooled
down, then press the specific circuit breaker
button to reactivate the power supply and
motor operation
Make sure that the amount of detergent
solution in the solution tank is sufficient for
the work to be carried out, and if necessary
fill the solution tank.
POS.
1
CONTACT BREAKER 16A
2
SWITCH 20A
3
START RELAY
4
START CONDENSER
5
WORK CONDENSER
6
MOTOR 1100W 100/115V 50/60HZ
8
PLUG
BK
BLACK
BU
BLUE
BN
BROWN
RD
RED
WH
WHITE
GNYE
YELLOW/GREEN
COMPONENT

Publicidad

Tabla de contenido
loading

Tabla de contenido