Installation
Electrical Installation
WARNING: The installation of the electric fireplace must comply with the applicable Local and/or National
Electrical Codes and utility requirements.
CAUTION: A dedicated 15 Amp circuit is recommended, rated for the appropriate voltage (120 V, 240 V). A
dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis
when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the
circuit breaker.
120 V Hardwire Installation
WARNING: Use the appropriate wire to meet local and national electrical codes for rated power
consumption.
!
NOTE: For OLF86-AM, heat function cannot be used when supplied with 120 V.
1. Cut the wire to an appropriate length.
2. Connect the black L1 wire from the unit to the live wire from the power supply with a wire connector.
3. Connect the white N wire from the unit to the neutral wire from the power supply with a wire connector.
4. Connect the green G wire from the unit to the ground wire from the power supply with a wire connector or
attach the grounding wire to the cover with the provided grounding screw, by placing the wire in between
screw and lock washer and tighten.
5. Ensure all wire connections are tight.
14
Figure 10
WHITE - N
BLACK – L1
RED – L2
GREEN - G
WHITE - N
BLACK – L1
RED – L2
GREEN - G
WHITE – N
120 V
POWER
BLACK – L
SUPPLY
(BREAKER
PANEL)
GREEN - G
WHITE – N
240 V
BLACK – L
POWER
SUPPLY
(BREAKER
RED – L2
PANEL)
GREEN - G