Pump without follower plate
B
1
Switching parts of low-level control for grease (when reservoir is filled).
1 Pivot bracket with round magnet
3 Control cam
A Inner orbit of round magnet
B Position of pivot bracket (LL not activated)
Indicates change.
*
Grease reservoir full
of grease
• Stirring paddle rotates clockwise during
lubrication cycle († Fig. 13).
• Pivot bracket of stirring paddle (B) is
completely submerged into grease and
grease resistance to paddle rotation
guides bracket with round magnet 1
inward to orbit (A).
• Control cam (3) guides pivot bracket with
magnet outwards, in direction of reservoir
wall. Since reservoir is full, grease
resistance guides pivot bracket inward to
orbit (A) as soon as bracket passes
cam (3).
A
• Magnet and low-level switch (2)
(† Fig. 14, page 17) are not aligned and
switch can not be activated.
NOTE
Above mentioned switching parts (1 to 3)
(† Fig. 13 and 16, page 19) must not be
used with fluid grease or oil. In this case, use
float magnetic switch.
16
Fig. 13*
3