Fig. 19
Connect to water supply
Garden hose
6. If only using the base unit, turn the water supply tap on
completely.
7. Push the safety lock on the spray gun handle, then press
the trigger for a few seconds until the water flow is steady.
Operating the pressure washer in this manner will allow
air to escape and discharge residual pressure in the hose
(Fig. 20).
Fig. 20
8. Keeping the trigger pressed, turn on the unit by pressing
the On/Off button on the control panel. Using the "Pressure
Select" feature, you can also choose from three different
pressure settings by pressing the + or - button on the right
side of the control panel (Fig. 21).
Fig. 21
Safety lock
Trigger
Control panel
NOTE: This machine is equipped with 3 selectable power/
pressure levels. See table below for detailed specs.
Light
Power
indication
– Off
Low
– Off
– On
– Off
Medium
– On
– On
– On
High
– On
– On
9. When re-starting the motor, always keep the trigger
pressed.
NOTE: The motor only runs when the trigger is operated
and shuts off when the trigger is released.
Using the Nozzles
Before beginning any cleaning task, determine the best nozzle
for the job. Each nozzle has a different spray pattern. The
nozzle patterns are 40˚ (for gentle cleaning), 25˚ (for all-purpose
cleaning), 15˚ (for tough jobs), and 0˚ (for spot cleaning or hard-
to-reach areas) .
m
CAUTION!
NEVER change nozzles without locking the
safety lock on the trigger handle.
m
WARNING!
High-pressure jets can be dangerous if
subject to misuse. The jet must not be directed at persons,
pets, live electrical equipment, or the appliance itself.
This cordless pressure washer is equipped with four (4) Quick-
Connect nozzles that easily snap onto the Quick-Connect
collar of the spray wand.
To connect a nozzle to the spray wand:
1. Turn off the pressure washer, remove the bucket or shut
off the water supply. Pull the trigger to release water
pressure.
2. Lock the safety lock on the trigger handle by pushing on
the safety lock until it clicks into the slot.
3. Pulling the quick-connect collar backwards, at the same
time, snap the desired nozzle onto the quick-connect
collar until it clicks into place, then release the quick-
connect collar (Fig. 22).
Fig. 22
Spray wand
Quick-Connect collar
13
Rated
Rated flow
pressure
0.68 GPM
507 PSI
0.74 GPM
650 PSI
0.79 GPM
800 PSI
Nozzle
"Click"