Installation
Earthing Instructions
Warning
This equipment must be earthed.
RC517*/RC519* requires a dedicated 230 volt, 16 amp
50 hertz circuit. Oven main lead wires are colored as
follows:
• Earth—Green and Yellow
• Neutral—Blue
• Live—Brown
If oven main lead wire colors do not correspond with
terminal plug markings or colors, match plug terminals
according to following markings:
• E—Earth
• N—Neutral
• L—Live
Unpacking Equipment
• Inspect equipment for damage such as dents in
door or dents inside oven cavity.
• Report any dents or breakage to source of
purchase immediately. Do not attempt to use oven
if damaged.
• Remove all materials from oven interior.
• If oven has been stored in extremely cold area, wait
a few hours before connecting power.
Equipment Placement
• Do not install equipment next to or above source of
heat, such as pizza oven or deep fat fryer. This
could cause microwave oven to operate improperly
and could shorten life of electrical parts.
• Allow air flow around oven. Air flows around electric
components. At least 1½ inch of clearance is
required at top and sides of equipment to provide
proper ventilation. With restricted air flow oven may
not operate properly and life of electrical parts is
reduced.
• Allow 6.5 centimeters / 2
discharge on back of equipment and back wall.
• Do not block or obstruct oven filter. Allow access
for cleaning.
9
/
inches between air
16
Radio Interference
Microwave operation may cause interference to radio,
television, or similar equipment. Reduce or eliminate
interference by doing the following:
• Clean door and sealing surfaces of oven according
to instructions in Care and Cleaning section.
• Place radio, television, etc. as far as possible
from oven.
• Use a properly installed antenna on radio,
television, etc. to obtain stronger signal reception.