545150011
HEATER STAND AND LOCATION
This heater is intended for outdoor use only. Always ensure that adequate fresh air ventilation
•
is provided.
•
Always maintain proper clearance to combustible materials, i.e. top 120 cm and sides 100 cm
minimum.
The heater must be placed on firm level ground.
•
•
Never operate the heater in an explosive atmosphere like areas where gasoline or other flammable
liquids or vapors are stored.
To protect the heater from strong wind, anchor the base securely to the ground with screws.
•
GAS REQUIREMENTS
Use propane only.
•
Maximum inlet pressure of propane regulator must not exceed 100 PSI.
•
The pressure regulator and hose assembly used must conform to local standard codes.
•
The installation must conform to local codes, or in the absence of codes, with standard codes.
•
The installation must conform to local codes, or in the absence of codes, with the standard for
•
storage and handling of propane gases.
A dented, rusted or damaged propane tank may be hazardous and should be checked by your
•
tank supplier.
Never use a propane tank with a damaged valve connection.
•