The propane tank must be arranged to provide for vapor withdrawal from the operating
cylinder.
Never connect an unregulated propane tank to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas
tightness check must be performed at the installation site due to possible mishandling in
shipment or excessive pressure being applied to the heater.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF position.
Make a soap solution of one part liquid detergent and one part water. The soap solution can
be applied with a spray bottle, brush or rag.
Soap bubbles will appear in case of a leak. For leakage test points see pictures below. Turn the
gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply
on and recheck. Contact your dealer for assistance if bubbles continue to appear.
Never leak test while smoking.