Responsibility of the customer
Supply voltage
Ground
FIGURE 8.2- SINGLE-PHASE ELECTRICAL
CONNECTION SCHEME (MOTOR WITHOUT
THERMAL PROTECTION)
5. Assembly and adjustments:
ATTENTION
to read and understand all instructions found in the following pages of this manual. All adjustments must be
made as indicated in this manual and always with the drill disconnected from power.
5.1. Column assembly:
• Place the column set on the base 8 .
• Align the holes of the column 4 support with the base 8 ones.
• Fix the column using the bolts supplied (Figure 8.3)
5.2. Table assembly:
• Remove the safety ring from the column (model 16).
• Slide the table clamp with table 5 connected to the toothed rack 18* and its support.
• Tighten the clamp by turning the Table Crank (Figure 8.4).
• Install the safety ring (model 16).
• To connect the crank to the toothed rack, loosen the Table Lever (Figure 8.9), lift or lower the table by
turning the crank.
* Model 13 model doesn't have toothed rack.
B
Plug 2p+g
N
To avoid injuries related to unexpected movements during the drill assembly, you have
Note:
- For motor protection, the orientations of Figure 8.2 must
be followed.
- The electrical network must not present voltage variations
superior to ± 10%.
- The voltage drop caused during the start-up must not be
superior to 10%.
- Use retarded fuse.
- Expenses related to installation and accessories are
client's responsibility.
F1
D" or "NH" fuse type (see Table 8.1)
K1
Overload relay (must be adjusted to the nominal current of the electric
FT1
S
M
B1
S1
N
51
Three-pole contactor
motor)
Start switch
Electric Motor
Emergency Button
On / off switch
Neutral