VHS120
Technical data
Parameter
Voltage @50/60 Hz
Power rating
Power rating (EN 60335-2-69)
Max vacuum
Maximum air flow rate without hose and
reductions
Maximum air flow rate (3 m Ø 50 mm hose)
Sound pressure level
(Lpf) (EN60335-2-69) (*)
Vibration, ah (**)
Protection
Insulation
Container capacity
Longopac® dust bag capacity
Vacuum inlet (diameter)
Allowed hoses
Primary filter surface (L-M)
Upstream H absolute filter surface
Absolute filter efficiency according to MPPS
method (EN 1822)
(*) Measurement uncertainty KpA < 1.5 dB(A). Noise emission values obtained according to EN-60335-2-69
(**) Total value of vibration output to the operator arm and hand
Dimensions
Model
A (mm)
B (mm)
C (mm)
Weight (kg)
I
GB
■
Storage conditions:
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
F
■
Operating conditions:
Maximum altitude: 800 m
D
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
E
C438
Figure 4
VHS120 L
VHS120 M/H
600
600
1000
1300
40
55
[ NOTE ]
Units of
measurement
V
110
kW
kW
1.5
mBar
m
/h
300
3
m
/h
250
3
dB(A)
m/s
2
IP
Class
L
L
mm
mm
m
2
m
2
%
8
VHS120
230
2
1.8
210
330
285
74
≤2.5
44
I
37
-
50
50
1.6
1.6
99.995 (H14)