Test = test input (see Additional functions)
UL: Only for use in applications in accordance with NFPA 79. These devices shall be
protected by a 1 A fuse suitable for 30 V DC.
Adapters listed by UL with connection cables are available.
Enclosure type 1.
Align the sender (GRS18) with the receiver (GRE18). Select the position so that the red
emitted light beam hits the receiver. Tip: Use white paper or a reflector as an alignment
aid. The sender must have a clear view of the receiver, with no object in the path of
the beam [see
figure
4]. You must ensure that the optical openings (front screen) of the
sensors are completely clear.
Figure 4: Alignment
Sensor with potentiometer:
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
Operating reserve increased; counterclockwise rotation: Operating reserve reduced. We
recommend setting the potentiometer to "Maximum".
The sensor is adjusted and ready for operation. Refer to Graphics C and G to check the
function. If the switching output fails to behave in accordance with Graphic C, check the
application conditions. See section Error analysis.