5.
Allow the solution to circulate in the water system for 30-40 minutes and then set the ice-wash switch to the OFF position.
6.
To purge out the ice machine scale remover and residue move the ice-wash switch to the WASH (the machine will drain the
reservoir and refill it) and then set the ice-wash switch to the OFF position.
7.
Disconnect power and water supplies.
8.
Mix a cleaning solution.
9.
Remove shield and water tray.
10.
Clean the metal surfaces of the thickness sensor, water level sensor, the adjustment screw, the shield and the water tray with
the cleaner solution using a brush (not a wire brush) or cloth.
11.
Clean the interior surfaces of the freezing compartment (including walls, plastic parts of the evaporator, distributor...) and the
front panel with the cleaner solution using a brush or cloth.
12.
Mix a solution of sanitizer using approved (EPA/FDA) sodium hypochlorite food equipment sanitizer to form a solution with 100 t
200 ppm free chlorine yield.
13.
Sanitize all surfaces of the ice thickness sensor, water level sensor, shield and water tray applying liberally the sanitizer solution
using a cloth or sponge.
14.
Sanitize the interior surfaces of the freezing compartment (including walls, plastic parts of the evaporator, distributor...) and the
front panel applying liberally the sanitizer solution using a cloth or sponge.
15.
Return the water tray and shield to their normal positions.
16.
Connect power and water supplies.
17.
To start a sanitation cleaning cycle, move the ice-wash switch to the WASH position. The machine will drain the reservoir and
refill it. Pour the sanitizer into the water reservoir to get a solution as in the point 12.
18.
Allow the solution to circulate in the water system for 20 minutes and then set the ice-wash switch to the OFF position.
19.
To purge out the sanitizer solution and residue move the ice-wash switch to the WASH position (drain and refill) and allow the
water to circulate for 5 minutes and then move the switch to the OFF position (drain). Repeat this operation two more times to rinse
thoroughly.
20.
Return the panel to their position.
21.
Set the ice-wash switch to the ON position (position I) and discard the first two harvests.
Water level
sensor
Shield
13
Adjustment
screw
Thickness
sensor