Start-Up
1.- Previous Checkup
a) Is the machine leveled?
b) Voltage and frequency are the same as those on the nameplate?
c)
Are the discharges connected and operating?
d) Will the ambient temperature and water temperature remain in the following range?
MAXIMUM
MINIMUM
e) Is water pressure appropriate?
MINIMUM
MAXIMUM
NOTE: In case input water pressure is higher than 85 psi (6 bar), install a pressure regulator.
2.- Start-Up
Once the installation instructions are followed (ventilation, site conditions, temperatures, water quality, etc.), proceed as follows:
1. Open the water inlet. Verify the no existence of leakages.
2. For undercounter models open the door and remove the protection elements on the shield. For modular models remove the two
locking screws on top of machine, take off the front panel and remove protection elements on the shield and on the thickness
sensor.
3. Verify that the shield moves freely. For modular models verify also the thickness sensor moves freely.
4. Connect the machine to the power supply.
5. For undercounter models: push the blue switch on the machine front side. For modular models: push the blue switch found on
the back of the machine and then set the ice-wash switch to the position I.
6. Verify that there are no vibrations or frictions on the elements.
7. Verify that the water fall to the evaporator is occurring uniformly and all ice cubes are properly watered.
8. Close door (for undercounter models) / Replace the front panel in its place (for modular models).
9. For modular models verify the ice slab with the pictures below through the thickness sensor which needs to be regulated. In
case of undercounter models, to adjust the switches according to tables shown on the label placed on top cover.
Modular Models
Too Big
Just Right
Too Small
Damages due to the lack of maintenance and cleaning operations are not included on the warranty.
ROOM
109º F / 43º C
95º F / 35ºC
43º F / 10º C
35º F / 5ºC
14 psig (1 Bar)
85 psig (6 Bar)
Undercounter Models
Thickness Sensor
8
WATER