Symbols on the unit
Installation and connection
Installing the unit
To be taken into consideration for planning:
• For operation at a swimming pond: Install the unit at a distance of at least min. 6.6 ft (2 m)
from the water.
• For operation at a pond: You can install the unit directly at the edge of the pond.
• Protect the pressure filter from direct sunlight.
• Route the return to the pond so that the water is returned to the pond e.g. through a water
course. This enriches the water with additional oxygen.
• Ensure that the inlet into the pond is max. 6.6 ft (2 m) above the filter lid.
Bury the pressure filter
A buried container is barely visible. The FiltoCap stone gray (art. no. 91645) cover for the filter lid,
available as an accessory, blends seamlessly into the pond landscape.
• Dig a hole close to the pond and place the container in the hole down to the maximum em-
bedding depth.
• Ensure that the ground is firm and horizontal.
10
Read the operating instructions.
FiltoClear
3400
5200
8200
Embedding depth h
0.8 ft (0.24 m)
1.2 ft (0.36 m)
1.6 ft (0.48 m)