Establishing the connections
Hoses with a diameter of 1½ in (38 mm) or 2 in (50 mm) can be connected to the pressure filter.
The corresponding hose connectors are part of our scope of delivery.
Use hoses with a diameter of 2 in (50 mm) to keep the pressure loss in the hoses as low as
possible.
If you use a filter starter for start-up, fill the product into the container prior to carrying out
the following installation steps.
− It is easier to remove the filter cover if you first remove all hoses from the filter cover.
Connecting the inlet
Only use pressure hoses approved for at least the maximum pump pressure to connect the out-
let of the filter pump and the inlet of the pressure filter.
• Always use a hose clip to fasten the hose on a hose connector.
Connecting the outlet
Use a transparent hose connector with a flow lug. The transparent hose connector will allow you
to assess the water quality after filtration. The flow lug will show you the water flow.
• Push the hose onto the hose connector until only two segments on the hose connector re-
main uncovered.
– This will give you a sufficiently large view into the hose connector.
• Always use a hose clip to fasten the hose on a hose connector.