Instruction Manual
GB
Electric Breast Pump EasyStart
This electric breast pump is designed for expressing excess milk. It is not intended for expressing milk when a hungry baby cannot empty the breast
themselves, i.e. in all cases when your milk ducts are blocked. Doctors recommend breast milk as the best food for babies in the first year of life, which
should be combined with solid food from 4-6 months of age. Remember that your milk is the food that fully meets your baby's needs and it has
antibodies that protect your baby from infections and allergies.
WHAT IS IN THE SET, fig 1
1.
Upper diaphragm case
2.
Diaphragm – 1 pc
3.
Silicone massage cushion
4.
Funnel cover
5.
Breast pump body with funnel
6.
Silicone valve – 1 pc
HOW TO ASSEMBLE / DISASSEMBLE / CHANGE BATTERY Fig 2
2.1. Place the silicone massage cushion on the funnel. Make sure it fits tightly to the edges of the cup.
2.2. Place the diaphragm in the body with the funnel and close the upper diaphragm case.
2.3. Place the silicone valve, and make sure it fits tightly to the edges of the hole.
2.4. Screw the milk container onto the breast pump body using the adapter.
2.5. Attach one end of the silicone tube to the breast pump body and the other to the connector on the electric unit.
2.6. The device can be powered by four AA alkaline batteries (batteries are not included in the set).
2.7. While at home, you can use the breast pump powering it via a power adapter.
HOW TO USE BREAST PUMP, figs 3, 4, 5
Make sure that the breast pump has been cleaned and disinfected before. Wash your hands and breast thoroughly. To check if the milk ducts aren't
clogged, express a little bit of milk by squeezing the nipple gently.
Connect the breast pump to the power supply. Press the on/off button (fig.3). If the breast pump is turned on, the indicator above the button shall
light. To turn the breast pump off, press the on/off button again. After turning it off, the indicator will go out.
Place the breast pump against the breast so that the silicone massage cushion fits the breast evenly and prevents airflow. If there is an air leak, the
effectiveness of the breast pump can be significantly reduced. Always hold the bottle upright so that the breast milk can flow to the bottom of the
bottle freely.
The breast pump allows you to adjust the rhythm and strength of the suction to suit your individual needs.
Press the mode button (fig. 4) to regulate the suction rhythm and select one of the three modes:
• express – start-up mode
In the start-up mode, the breast pump mimics rapid and shallow sucking movements of the baby occurring during the stimulation phase. The start-
up mode is used to stimulate lactation. During the stimulation phase milk starts to flow out from the breast.
• natural – natural mode
The natural mode imitates slower, deeper and natural suckling movements that occur during effective suckling of the baby.
• strong – strong mode
The strong mode imitates slower, very deep suckling movements occurring during your baby's effective suckling.
When the milk starts to flow, the baby must put more effort into suckling. Milk slowly becomes denser and more filling; that is why the suckling
rhythm and the pace slow down.
Thanks to the knob (fig. 5) you can adjust the suction power smoothly.
1. low suction strength
2. medium suction strength
3. high suction strength
Express milk from one breast until you feel that milk starts to flow slower. Place the breast pump against the other breast and continue expression.
After finishing, unscrew the bottle from the breast pump and attach the teat with the cap. The milk is ready for your baby.
12_215reb_instrukcja_ms001.indd 2-3
12_215reb_instrukcja_ms001.indd 2-3
Model 12/215
7.
Adapter for wide- and narrow-neck bottles
8.
Milk container 120 ml
9.
Tube
10. Electric unit
11. Connector
12. Power adapter
2
HOW TO CLEAN AND DISINFECT BREAST PUMP PARTS
Cleaning process:
Disassemble the following parts of the breast pump: upper diaphragm case (1), diaphragm (2), breast pump body with funnel (5), silicone massage
cushion (3), funnel cover (4), silicone valve (6), container (8) and adapter (7) before using the breast pump for the first time. Wash in hot water with
mild detergent and rinse thoroughly. Disinfect by placing it in boiling water for about 5 minutes. Dry thoroughly before assembly and subsequent
use. NOTE! After disinfection wait until all parts have cooled down. Do not start assembling the body when the parts are warm or moist as it can
cause breast pump malfunction. Check that the individual parts of the breast pump are correctly attached.
Cleaning instructions: Disconnect the silicone tube and the connector from the breast pump. These elements do not require cleaning because the
diaphragm protects them from contact with food. All parts of the breast pump should be washed by hand in hot water with mild detergent. Do not
use strong detergents or rough materials that can scratch the surface. Rinse with clean, hot water.
NOTE! Always remove the anti-return valve by grasping its round base with two fingers. Never grasp the tip of the valve, as it can be damaged what
can weaken the suction power. Wash the non-return valve very gently and do not allow food to dry inside it.
NOTE! Do not wash the silicone tube and the connector and especially do not wash electrical components.
Wipe with a damp cloth.
HOW TO CLEAN AND DISINFECT bottle/container
Thoroughly wash and disinfect the milk container and its components before the first and each subsequent use. Place it in boiling water for 5 minutes
to ensure hygiene. Clean before each use. Boiling and hard water may create a limescale effect. Wash all parts thoroughly with clean water, including
areas that may not be visible but through which food has passed, to remove any food residue. After use, clean the milk container of milk residues,
rinse, wash and then disinfect in a steam/electric steriliser or boiling water. The milk container can be used in a dishwasher (max. temp. 60°C). Do
not use antibacterial agents for cleaning. Take special care when heating food in a microwave. Always stir heated food to ensure even distribution
of temperature and check the temperature before feeding. If you heat food in a microwave, remember that the milk container must be open. The
product should not be placed in a preheated oven or heated on a gas or electric stove.
For your child's safety and health. Note! Check the product before each use. Throw away at the first signs of damage or weakness. Warning!
This product is not a toy. Keep out of reach of children. ALWAYS check food temperature before feeding. Maintain maximum hygiene when using
containers. DO NOT boil the breast milk. DO NOT add fresh breast milk to defrosted milk. NEVER refreeze previously defrosted milk. NEVER fill
containers with hot liquids. ALWAYS use this product under adult supervision. For breast milk only. Do not use it to prepare modified milk.
WARNING!!!
The device is intended for personal use only. Use by more than one person may pose a health risk. The device comes with a 24-month manufacturer's
warranty. Please keep your proof of purchase of the device. Before using, read the user manual and follow the rules of safe use. Keep this user manual
together with the device. The expected lifetime of the product is five years. The expected lifetime of silicone components is no more than two years.
Silicone components may change their colour permanently. Replace silicone components after finding discolouration or after the estimated time of
use.
FOLLOW THE INSTRUCTIONS BELOW STRICTLY. THE MANUFACTURER IS NOT LIABLE FOR DAMAGES RESULTING FROM IMPROPER USE OR USE
INCONSISTENT WITH THIS USER MANUAL. ANY DAMAGES ARISING FROM MISUSE CAN NOT BE THE BASIS FOR COMPLAINTS OR REPAIRS UNDER
WARRANTY.
Making any repairs or modifications to the product by an unauthorised person results in loss of warranty and may result in risks to health and life.
GENERAL SAFETY RULES
When using electrical devices, take the following safety precautions.
NOTE: To protect against electric shock, do not immerse the power adapter, power cable or breast pump body in water or any other liquid.
•
Protect the device from getting wet, and DO NOT operate the device with wet hands.
•
Before you plug in the device for the first time, ensure that the voltage is compatible with your electricity supply by checking the label on the base
of the unit. The correct voltage is 100-240 V.
•
Connect the device only to an efficient and surge-protected mains supply.
•
If needed, use only an adequately connected and protected extension cord.
3
28.11.2022 11:23:29
28.11.2022 11:23:29