Assembly; Packing List - Ryobi P2803 Manual Del Operador

Ocultar thumbs Ver también para P2803:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

UNPACKING
This product requires assembly.
 Carefully remove the product and any accessories from
the box. Make sure that all items listed in the packing list
are included.
WARNING:
Do not use this product if any parts on the Packing List
are already assembled to your product when you unpack
it. Parts on this list are not assembled to the product by
the manufacturer and require customer installation. Use
of a product that may have been improperly assembled
could result in serious personal injury.
 Inspect the product carefully to make sure no breakage
or damage occurred during shipping.
 Do not discard the packing material until you have carefully
inspected and satisfactorily operated the product.
 If any parts are damaged or missing, please call
1-800-860-4050 for assistance.

PACKING LIST

Chemical Sprayer
Hose
Measuring Cap
Spray Wand Assembly (Includes o-ring, threaded coupling,
and nut)
Handle
Replacement Seals
Quick Release Shoulder Harness
Operator's Manual
WARNING:
If any parts are damaged or missing do not operate this
product until the parts are replaced. Use of this product
with damaged or missing parts could result in serious
personal injury.
WARNING:
Do not attempt to modify this product or create
accessories not recommended for use with this product.
Any such alteration or modification is misuse and could
result in a hazardous condition leading to possible serious
personal injury.

ASSEMBLY

To prevent accidental starting that could cause serious
personal injury, always remove the battery pack from the
product when assembling parts.
CONNECTING THE SPRAY WAND TO THE
HANDLE
See Figure 2.
 Insert the spray wand into the the handle as shown.
 Slide the o-ring down until it touches the handle.
 Install the threaded coupler onto the handle and tighten
securely.
 Rotate the nozzle until it is aligned with the handle (pointing
down) and ready for use.
 Slide the nut onto the threaded coupler and tighten
securely.
 Pull on the spray wand to be certain it is properly secured.
 Place the assembled handle into the handle storage area.
ATTACHING THE HOSE
See Figures 3 - 4.
To attach the hose to the tank:
 Slide the nut on the hose away from the hose end.
 Insert the hose end into the hose connector as shown.
Make sure the connection is secure.
 Slide the nut over the opening and hose end. Hand tighten.
Do not overtighten.
To attach the hose to the handle:
The hose comes preassembled to the handle. If it becomes
loose, follow the instructions below.
 Install the threaded coupler onto the handle and tighten
securely.
 Slide the nut on the hose away from the hose end.
 Insert the hose end into the opening on the threaded
coupler. Make sure the connection is secure.
 Slide the nut over the hose and threaded coupler. Hand
tighten. Do not overtighten.
ATTACHING THE QUICK RELEASE SHOULDER
HARNESS
See Figure 5.
To prevent back and shoulder fatigue, always use the quick
release shoulder harness when operating this tool. If your
back or shoulders become sore, take a break and then adjust
the position of the harness.
 Squeeze and hold the latch on the spring clip.
 Place the spring clip onto the strap hanger and release
the latch.
 Repeat to secure second spring clip.
 Place the strap around your shoulder and adjust it to a
comfortable position.
6 — English
WARNING:

Publicidad

Tabla de contenido
loading

Tabla de contenido