Step 3: If pairing is successful, the green LED on the receiving detectors will stop flashing. When there is an error the
green light will continue to flash for 60 seconds followed by a red light for 2 seconds.
How to unlink a smoke detector
Press the test/silence button on the smoke detector twice within 1 second and the green LED will slowly flash for 60
seconds (receiving mode). After this period, it will stop flashing and the smoke alarm is unlinked.
Maintenance and cleaning
1. Test the smoke detector once a month.
2. Do not paint the smoke detector. Paint will seal the vents and interfere with the sensor's ability to detect smoke.
3. Never attempt to disassemble the smoke detector to clean inside. This will damage the alarm.
4. Clean the smoke detector at least once a month to remove dust, dirt or debris. Use a vacuum cleaner with a soft
brush and vacuum all sides and covers of the smoke detector.
Trouble shooting
Problem
The smoke detector does
not sound when testing
Red LED flashes and the smoke
detector delivers one beep every
60 seconds
The smoke detector delivers one
beep every 40 seconds
Nuisance alarms triggered
intermittently or when residents
are cooking, taking showers, etc.
Method of disposal
Please check whether the smoke detector is activated.
The battery is low.
1. Clean the smoke detector, please refer to the "maintenance and
cleaning" section.
2. The alarm is malfunctioning. Contact the retailer to replace it if the
warranty is still in place.
1. Press test button to put smoke detector in silence mode.
2. Clean the smoke detector. Please refer to the "maintenance and cleaning"
section.
3. Move the smoke detector to a new location.