EN
INSTALLATION OF THE DETECTORS
The Installation Diagram of Magnetic Door Detector:
CAUTION:
A: The gap between the magnet and the sensor should be less than 10mm. B: After
the installation, if the indicate light of the detector is on when the door is open. It
proves it is installed successfully.
C: If the indication light of the door detector flashes when it is triggered, it means the
battery of the sensor is in low voltage, and you need to change the battery as soon as
possible.
D: The transmit distance of the detectors is less than 100meters in the open area,
please test the distance before installing. The obstacles will change the transmitting
distance.
The Installation Diagram of PIR Motion Detector:
To avoid the false alarm, please pay attention to the
following point in stalling the PIR motion detector;
A: Do not face the glass window.
B: Do not face the big object which is easy to swing.
C: Do not face the cold and heat air vent or cold and heat
source.
D: The furniture, mini escape or any other isolation should
be away from the detecting scope.
E: Do not install two or more detectors in the same area or
it will cause the interference when alarm.
F: When the detector is triggered and the LED indicator
flashes, it means the battery is in low voltage, please
change it as soon as possible.
57