Operation
5.8
Stationary Cooling (supplementary equipment)
!
CAUTION!
Ensure that the protective cover of the 230 V device plug on the vehicle is
always closed when the stationary cooling is not on.
Switching on the stationary cooling
The stationary cooling may only be operated under the following conditions:
The vehicle must be on even ground so that the condensation can drain away
The vehicle engine must be switched off and the ignition key removed
All cargo space doors must be securely shut
!
CAUTION!
Always connect the 230 V connection cable on the vehicle first before con-
necting the stationary cooling to the 230 V power supply.
Before you start the vehicle again, you must disconnect the 230 V power
supply cable again from the socket on the vehicle.
The 230 V power supply connection of the stationary cooling may only be
operated with a fault current protected switch with a nominal current of
30 mA and an earthed, splash water-protected power supply socket.
Handle the 230 V connection cable with care so that it cannot be damaged
by heat, movement or sharp objects.
If the 230 V connection cable has been stretched or pulled in any way, you
must check whether the 230 V device plug or other parts on the vehicle
have been damaged. Damaged cables must be replaced.
Only use the original 230 V connection cable with the original 230 V
MiniPlug device plug.
Only use contact spray that is suitable for electrical components when
cleaning the electrical contacts and contact pins under the protective cover
of the 230 V device plug.
Check the contacts, the cover and also the 230 V connection cable for
damage before and after use. If the contacts, the cover or the connection
cable are damaged, these must be replaced.
I
NOTE
The 230 V connection cable has also been especially designed and tested for
use at cold temperatures. The connection cable will not incur any damage dur-
ing normal winding at very low outside temperatures, even if the cable feels
stiffer the colder it gets.
To switch on the stationary cooling, proceed as follows:
➤ Park the vehicle on a level surface.
➤ Turn off the vehicle's engine and remove the ignition key.
➤ Ensure all cargo space doors are securely closed.