3. Press the programming button (PROG button) (D).
ð The display shows "8".
4.9.4 Menu 8: Door adjustments
NOTICE
After the setting was changed, the force learning cycle must be re-
peated.
1. Select menu item "8".
ð After approximately 2 seconds, the display flashes and the set value
appears. The factory setting is "4". For optimal movement and to maintain
the forces, select the corresponding door type.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
Menu value
0
1
2
3
4
5
6
7
8
9
3. Press the programming button (PROG button) (D).
ð The display shows "9".
62 - EN
Door type
Double swing gate
Non-swinging door, Canopy
Swing door, tilting door, normal
Swing door, tilting door, sensitive running
Universal setting (factory)
Sectional door with tension spring fitting (Topspeed)
Sectional door with torsion spring fitting (Topspeed)
Industrial door with standard fittings
Side section door (Topspeed)
Side section door with secondary closing edge