The data plate is on the front panel (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, ECI norms.
The appliance is supplied without the electric connection cable. To install the power supply cable, proceed as follows:
•
Disconnect the power supply.
•
Remove the front panel
GB
TECHNICAL DATA TABLE
FT...D-64ET... FT...D-66ET... FT...D-68ET... FTCD-64EM
400Vac3N
400Vac3N
50/60Hz
50/60Hz
6,5 A
13 A
4,5 kW
6 kW
5x1 mm²
5x1,5 mm²
TRANSFORMATION
FT...D-64ET... FT...D-66ET... FT...D-68ET... FTCD-64EM
230Vac3
230Vac3
50/60Hz
50/60Hz
11,3 A
17,8 A
4,5 kW
6 kW
4x1,5 mm²
4x2,5 mm²
FT...D-64ET... FT...D-66ET... FT...D-68ET... FTCD-64EM
230Vac 50/60Hz
26 A
6 kW
3x4 mm²
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
IE
400Vac3N
50/60Hz
13,1 A
9 kW
5x1,5 mm²
230Vac3
50/60Hz
22,6 A
9 kW
4x2,5 mm²
20
FTCD-66ET
230Vac
400Vac2N
50/60Hz
50/60Hz
11,3 A
11,3 A
2,6 kW
4,1 kW
3x1,5 mm²
4x1,5 mm²
FTCD-66ET
230Vac3
50/60Hz
15,6 A
4,1 kW
4x1,5 mm²
FTCD-66ET
230Vac 50/60Hz
17,8 A
4,1 kW
3x1,5 mm²