Descargar Imprimir esta página

eSolutions PULSAR PLUS Guia De Instalacion página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
INSTALLATION
NEMA plug-in installation
Refer to one of the corresponding sub-sections below for an existing NEMA outlet or for installing a new NEMA outlet.
Instructions for electricians to install a NEMA
outlet to be used with a Free2move Charge
Wallbox charger.
120V
14-50R 240V/50A "RV" outlet.
12
NEMA 14-50
240V
120V
NEUTRAL
X
Y
GROUND
Existing NEMA outlet
If you already have a NEMA outlet, ensure that:
• It complies with local electrical codes.
• It has a designated circuit breaker and
electrical wiring that are dimensioned
appropriately.
Switch off the circuit breaker of the electrical
outlet before installing your charger.
NEMA outlet installation
When installing a NEMA 14-50 outlet, be sure the
ground pin is facing down as shown in the diagram
on the left.
Important recommendations
• Ensure you have the correct permits for this
electrical installation.
• Remember that the NEMA outlet must be
placed on the left side of the charger as
shown at page 8.
• Keep in mind that the power supply cable
length is limited to 12" (30cm).
• Ensure the electrical panel supports a 240V
dedicated circuit with a new, dedicated two-
pole circuit breaker.
• CAUTION: To reduce the risk of fire, connect
only to a circuit with a branch circuit
overcurrent protection of 50A in accordance
with ANSI/NFPA 70 (US) C22.2 NO.280-13
(Canada).

Publicidad