MAINTENANCE
Caster Wheels
Check every 200 hours. Check that wheels rotate
freely. Foam filled tires or solid tires will void the
warranty.
To replace, remove nut and caster bolt. Pull the
wheel out of the yoke and take care with the
spacer. Reinstall in reverse order. Tighten the
caster bolt and torque to 45 ft-lbs (61 Nm).
NOTE: Tire must rotate freely but axle spacers
must not. If wheels do not rotate freely take the
unit to the dealer for service.
Battery
Your mower is equipped with a maintenance
free battery and does not need servicing.
However, periodic charging of the battery with an
automotive type battery charger will extend its life.
• Keep battery and terminals clean.
• Keep battery bolts tight.
• See chart for charging times.
Cleaning the battery and terminals
Corrosion and dirt on the battery and terminals
can cause the battery to lose power.
1. Lift the seat and rotate fully forward until
supported by the seat rod.
2. Loosen the two wing nuts attached to the side
J bolts just enough that the battery mount
bracket slides down off the battery.
24
3. Using two 1/2" wrenches disconnect BLACK
battery cable then RED battery cable.
4. Carefully remove the battery from the mower
5. Rinse the battery with plain water and dry.
6. Clean terminals and battery cable ends with a
wire brush until shiny.
7. Coat the terminals with grease or petroleum
jelly.
Replacing
1. Install the new battery with terminals in the
same position as the old battery.
2. Connect RED battery cable first to positive (+)
battery terminal.
3. Connect BLACK grounding cable to negative
(-) battery terminal.
4. Slide mount bracket back up over battery and
retighten wing nuts.
CAUTION! Always wear eye
protection when around batteries.
STD
STATE
BATTERY
OF
CHARGE
50 Amps
12.6V
100%
12.4V
75%
12.2V
50%
12.0V
25%
11.8V
0%
*Charging time depends on battery capacity,
condition, age, temperature and efficiency of charger
WARNING! Do not short battery
terminals by allowing a wrench or other objects
to contact both terminals at the same time.
Before connecting battery, remove metal
bracelets, wristwatch bands, rings, etc.
Positive terminal must be connected first to
prevent sparks from accidental grounding.
IMPORTANT INFORMATION Do not try
to open or remove caps or covers. Adding
or checking the level of electrolyte is not
necessary. Always use two wrenches for the
terminal screws.
APPROXIMATE CHARGING TIME*
TO FULL CHARGE AT 80
Maximum Rate at:
30 Amps
20 Amps
- FULL CHARGE -
20 min.
35 min.
48 min.
45 min.
75 min.
95 min.
65 min.
115 min.
145 min.
85 min.
150 min.
195 min.
F
O
10 Amps
90 min.
180 min.
280 min.
370 min.