60801860
28/2/05
12:39
ESQUEMAS DE CONEXIONADO
Negro / Schwarz / Noir
Black / Nero / Zwart / Preto
Azul / Blau / Bleu / Blue
Azzurro / Blauw / Azul
MT-100
MT-125
Página 18
Fig. 1
Luces u otra carga
Marrón / Braun
Leuchten oder andere ladung
Marron / Brown
Lumières et autre charge
Marrone / Bruin
Lights or other connection
Castanho
Luci o altra carica
Lampen of andersoortige belasting
Luzes ou outra carga
MT-100 TIMER
MT-125 TIMER
ELECTRICAL CONNECTION MT-100 AND
MT-125 WITH SUPPORT BRACKET
The extractor unit should be connected to a single phase supply network at the
voltage and frequency indicated on the extractor characteristics plate.
The electrical installation must be fitted with a single-pole switch with a distance
between contacts of at least 3 mm.
The unit should be connected to the power supply network before being installed in
the conduit (MT-100 and MT-125).
1) Loosen the screw (A) and remove the cover (B).
2) Perforate the plug (C) and thread the power cables through the hole.
3) Connect the power cables to the terminals fo the connection strip (D) and, once
connected fix it firmly between the pivots (E).
4) Insert the plug (C) in the hole between the housing (F) and the cover (B).
5) Replace the cover (B) and fix it in place using the screw (A).
The appliance must be permanently connected to a fixed installation of tubing and
power supply cable. (Rigid cable with two conductors of at least 1 mm
does not require an earth connection as the unit has double insulation).
2
section. It