Surrounding Air Temperature Rating
The devices are suitable for an ambient temperature of 40 °C, max. 60 °C with de-ra-
ted output current. To determine the output current rating at temperatures above
40 °C, the output current should be de-rated by 3 % per K between 40 °C and 60 °C.
For MOVIMOT
To determine max. output current rating at higher than 35 °C and depending from
mains voltage, the output current should be de-rated as follows:
Ambient tempera-
ture
30 °C – 35 °C
35 °C – 40 °C
40 °C – 55 °C
55 °C – 60 °C
Wiring Diagrams
For wiring diagrams, refer to chapter "Electrical Installation".
®
performance Units size 2 only:
..CM3C../DI..0070..
U
> 460 V
mains
3.5 % I
/K
N
Instrucciones de funcionamiento – MOVIMOT
Instalación eléctrica
Normas de instalación
I
-Reduction
N
..CM3C../DI..0095..
U
= 400 V
U
mains
mains
2 % I
1 % I
/K
2 % I
N
3 % I
/K
3 % I
N
3 % I
/K
N
®
performance DFC
5
> 460 V
/K
N
/K
N
/K
N
37