Safety instructions, Starting Operation
Before starting operation, check if lever is reset
automatically to starting position.
The outside condition of the hand nozzle has to be controlled
by regular visible checks. Regularly check swivel joint (hose
connector with o-ring), nozzle housing, outlet tube and safety
handle. These parts are particularly subject to wear and dirt
accumulation.
Regularly check the hose clamp for tight fit.
Check outlet tube and seal for tight fit. If necessary,
tighten again outlet tube and/or replace seal.
When using a hand nozzle with an attached key button,
only use the key button with a safety extra-low voltage.
Generally replace a defect signalling cable.
Only use the hand nozzle with safety handle.
Non-compliance with the safety instructions may cause
injuries to the operator, pollution of the environment or
damage to the hand nozzle.
Starting operation
Ensure that the supply voltage corresponds with
the voltage indicated on the name plate.
Never operate the pump unless the union nut between
motor and pump has been firmly tightened.
Immerse the pump vertically into the liquid and secure it in a
vertical position by the use of a barrel fitting or a screw clamp.
Always check power supply cable for damage before starting
operation.
Keep solvents away from the power supply cable.
Only switch the motor on when the pump is in the liquid.
Before inserting the plug to the socket, ensure that
on/off-switch is set to "0" (Stop).
Insert the plug.
Switch on the motor.
16