system.
MECHANICAL MEASURES:
Check the filter, the skimmer, the valves and the pipes are well connected to the pool. Do consider high water temperature will
involved more time for the filtering. Theoretic filtering time = Water volume / Filter system discharge (generally 8h/day with water
temperature of 21°C), (Ideal: 2h in the morning – 4h around midday – 2h in the afternoon). PLEASE RESPECT THE CONTINUOUS
WORKING PERIOD INDICATED IN THE FILTER MANUALS.
VACUUM CLEANER (MANUAL OR AUTOMATIC):
Only for pools with skimmer. Connect an hose extremity to the brush head and immerse it into the water to make it fill in. Connect the
other pipe extremity to the exhaustion adapter (TA) and place it above the skimmer basket. Switch on the filter in the FILTER position
and begin to clean the bottom. Pay special attention to areas with folds where dirt accumulates.
BOTTOM CLEANER VENTURY STYLE:
Connect a garden hose to the bottom cleaner join and introduce it into the pool. Open the tap until a normal pressure to make the
water flow out against the bottom of the pool, producing in that way an ascendant stream which leave the dirt into the filter (bag)
which is adjust on the bottom cleaner.
EFFECTS
Cloudy water
Green coloured
The pump does not start
The pump turns but does not discharge
The skimmer does not suck
Dirty water returned to pool
Pressure in pressure gauge too high
The pool cleaner does not suck or does
not suck enough
Corrosion marks
Sand in the pool
168
CAUSES
• Dirty filter
• pH incorrect
• Formation of algae
• Breaker disconnected
• Fuse burnt
• Turbine blocked
• Suction flaps closed
• The skimmer sucks air
• Pre-filter full
• Air inlet in the cover
• Defective turbine
• Basket full
• Flap not closed well
• Water level too low
• Filter obstructed
• Filter washing badly done
• Outlet flap closed
• Pre filter obstructed
• Corresponding flap closed
• Tube worn or perforated
• Air in the tubes
• Other flaps open
• Dirty filter
• pH very low
• Mesh broken
• Manipulation of the multi-directional
flap with the
pump working
• Filter inversely connected The tubes
have been inverted during assembly.
SOLUTIONS
• Washing the filter.
• Re-adjustment
• Shock treatment
• Re-start
• Replace it
• Check that the fan at the rear of the
motor turns
• Open them again
• Rectify water level
• Clean it
• Check the seal and change the pre-fil-
ter cover
• Change the turbine
• Empty it
• Open it
• Re-adjust it
• Wash it, rinse it
• Repeat it
• Open the trap, check condition of sand
(change it every 3 or 4 years)
• Clean it
• Open it
• Replace it
• Purge and wait for priming
• Close them
• Clean it
• Increase pH to 7,2-7,4
• Change the mesh
• Change the multi-directional flap
• Correctly connect the filter