PRODUCT DISPOSAL
This product is an integral part of the automation system it controls and
must be disposed of along with it.
As in the case of installation, likewise at the end of product lifetime the disas-
sembly and scrapping operations must be performed by qualified personnel.
This product is made of various types of material, some of which can be recy-
cled while others must be scrapped. Seek information on the recycling and dis-
posal methods envisaged by the local regulations in your area for this product
category.
Caution! – Some parts of the product may contain polluting or hazardous sub-
stances which, if released to the environment, may cause serious damage to
the environment or to human health.
As indicated by the symbol alongside, disposal of this product
with domestic waste is strictly prohibited. Separate the waste
into categories for disposal, according to the methods estab-
lished by current legislation in your area, or return the product
to the retailer when purchasing a new version.
Caution! – Local legislation may impose heavy fines in the event of illegal dis-
posal of this product.
7
PROGRAMMING
7.1 - Preset functions
The NAKED control unit has a number of programmable functions. These fun-
ctions are set to a configuration which should satisfy most automations.
7.2 - Programming keys
The NAKED control unit feature three keys that can be used to command the
control unit both during tests and programming.
Led
Function
L1
Automatic Closing
L2
Close After Photo
L3
Always Close
L4
Stand by
L5
Peak
L6
Pre-flashing
L7
"Close" becomes
"Open partially"
L8
Slave" mode
During the normal functioning of the NAKED, LEDs L1....L8 will either be on or off depending on the state of the function they represent. For example,
L1will be on if the "Automatic Closing" function is active.
TABLE 5 - Level one functions (ON-OFF functions)
Description
This function causes the door to close automatically after the programmed time has lapsed. The factory set Pause
Time is 30 seconds, but can be changed to 5, 15, 30, 45, 60, 80, 120 or 180 seconds. If the function is inactive,
functioning will be "semi-automatic".
This function enables the gate to be kept open for the necessary transit time only. In fact the "Photo" always causes
an automatic closure with a pause time of 5s (regardless of the programmed value).
The action changes depending on whether the "Automatic closing" function is active or not.
When "Automatic Closing" is inactive: The gate always arrives to the totally open position (even if the Photo
disengages first). Automatic closing with a pause of 5s occurs when the Photo is disengaged.
When "Automatic Closing" is active: The opening manoeuvre stops immediately after the photocells have disen-
gaged. After 5 seconds, the gate will begin to close automatically.
The "Close after photo" function is always disabled in manoeuvres interrupted by a Stop command.
If the "Close after photo" function is inactive the pause time is that which has been programmed or there is no auto-
matic closing if the function is inactive.
The "Always Close" function will trigger, and the gate will close if an open gate is detected when the power supply
returns. If the function is inactive when the power supply returns, the gate will remain still.
This function enables the user to lower consumption to a very minimum. It is particularly useful in cases when the
buffer battery is being used. If this function is active, the control unit will switch the BLUEBUS output (and conse-
quently the devices) and all the LEDs off one minute after the end of the manoeuvre. The only LED which will remain
on is the BLUEBUS LED which will simply flash more slowly. When a command arrives, the control unit will reset to
complete functioning. If this function is inactive, there will be no reduction in the consumption.
If this function is activated, the gradual acceleration at the beginning of each manoeuvre will be disconnected. It enables
the peak thrust and is useful whenever static friction is high, e.g. if snow or ice are blocking the leaf.If the thrust is inactive,
the manoeuvre will start with a gradual acceleration.
With the pre-flashing function, a 3 second pause is added between the flashing light switching on and the beginning
of the manoeuvre in order to warn the user, in advance, of a potentially dangerous situation. If pre-flashing is inactive,
the flashing light will switch on when the manoeuvre starts.
By activating this function all "close" commands ("CLOSE" input or radio command "close") activate a partial ope-
ning manoeuvre (see LED L6 on table 7).
By activating this function NAKED becomes "Slave": in this way it is possible to synchronise the functioning of two
motors on opposite leaves where one motor functions as Master and the other as Slave; for further information see
paragraph "8.1.5 NAKED in "Slave" mode".
Open
The "OPEN" key enables the user to control the opening
▲
of the gate or move the programming point upwards
Stop
The "STOP" key enables the user to stop the manoeuvre. If pressed
Set
down for more than 5 seconds it enables the user to enter programming
Close
The "CLOSE" key enables the user to control the closing of the
▼
gate or move the programming point downwards
7.3 - Programming
A number of programmable functions are available on the NAKED control unit.
The functions are adjusted using 3 keys set on the control unit: [▲] [Set] [▼]
and are used by means of 8 LEDs: L1....L8.
The programmable functions available on NAKED are set out on 2 levels:
Level one: the functions can be adjusted in modes ON-OFF (active or inactive).
In this case, each of the LEDs L1....L8 indicates a function. If the LED is on, the
function is active, if off the function is inactive. See Table 5.
Level two: the parameters can be adjusted on a scale of values (from 1 to 8).
In this case, each of the LEDs L1....L8 indicates the value set (there are 8 pos-
sible settings). Please refer to Table 7.
English – 7