Maintenance
Rinsing
It will take a few seconds for the detergent to clear. Apply safety latch to spray gun. Remove black soap nozzle
from the quick coupler. Select and install the desired high pressure nozzle.
NOTE: You can also stop detergent from flowing by simply removing detergent siphon tube from bottle.
Shutting Down And
Clean-up
STEP 1: Remove detergent suction
tube from container and insert into
one (1) gallon of fresh water. Flush
detergent lines with fresh water,
switch to the pump position and
continue to spray water allowing
burner to cool.
STEP 4: Squeeze trigger on spray
gun to relieve remaining pressure.
Move safety latch into its locked
position.
18
STEP 2: Turn burner switch off and
continue spraying, allowing the
water to cool to below 100°F. After
water has cooled, turn pump off.
Turn main gas valve off, then close
the valve on the LP tank. Secure
the LP tank to the machine when
moving it.
VHP 2-1500 / 3-2000 Operator's Manual 8.913-949.0 - AU
Pump Switch
STEP 3: Turn the water off. To
protect from freezing, pull the
trigger on spray gun to allow water
to drain from the system