General Safety; General Outline; Technical Specifications - BFT LEO MV D Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product
is in conformity with the following European Directives: 89/336/EEC and
73/23/EEC, 98/37/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

The LEO MV D control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display
programmer or by means of universal palmtop programmer. The Control
unit completely supports the EELINK protocol.
It is available in two versions: one for external installation, inside the SD box,
the other fitted and pre-wired inside the controller.
Its main characteristics are:
INSTALLATION MANUAL
-
Slow down of end-of-run speed.
-
Electronic torque setting
-
Adjustable electrodynamic braking
-
Closing / opening limit-switch inputs
-
Separate inputs for safety devices
-
Clock input
-
Serial protocol connection input (optional)
-
Incorporated radio receiver
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series of
pre-wired jumpers to facilitate the installer's work.
The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the
above-mentioned terminals are in use, remove their respective jumpers.

3) TECHNICAL SPECIFICATIONS

Power supply: ................................................................. 230V±10% 50Hz*
Mains/low voltage insulation: ........................................ > 2MOhm 500V
Dielectric strength: ........................ mains/low voltage 3750V
Motor output current: .................................................................... 1.5Amax
Maximum motor power: ..................................................................... 750W
Supply to accessories: ...................................... 24V
Gate-open warning light: ..................................................... 24V
Blinker: ................................................................................230V 40W max
Dimensions: ..............................................................................see figure 1
Fuses: .......................................................................................see figure 2
(* other voltages available on request)
4) TERMINAL BOARD CONNECTIONS (Fig.3)
WARNING – During the wiring and installation operations, refer to the cur-
rent standards as well as principles of good technical practice.
The cables must be tied by additional fastening next to the terminals, by
means of clips for example.
All the operator wiring operations must be carried out by qualified personnel.
JP1
1
2-3
JP2
4-5
6-7-8-9
JP3
10-11
12-13
JP4
20-18
20-19
Contact switching for barrier status control.
To be used in Parky systems (see paragraph 13)
JP5
JP8
21-22
21-23
21-24
21-25
21-26
21-27
21-28
21-29
21-30
21-31
JP9
32
33
38-39
GND terminal
Single-phase mains supply 230V±10% 50Hz (2=N) (3=L)
Blinker connection (mains voltage) 40W Max.
Motor connection:
6 operation 1 + capacitor
7 common (blue)
8 operation 2
9 capacitor
Output 24V~ 1A max – power supply for photocells or other
devices.
Gate-open warning light output (24V 3W max)
Barrier status output
Closed Contact with barrier raised
Closed Contact with barrier lowered
Encoder connection
WARNING! The maximum length of the connection cable of
the encoder should not exceed 3.00 mt.
Open-Close button (N.O. Start), key selector.
Block button (N.C. Stop). If not used, leave jumped.
Photocell input (N.C.). If not used, leave jumped.
Opening limit switch connection (N.C. SWO). If not used, leave
jumped.
Closing limit switch connection (N.C. SWC). If not used, leave
jumped.
Not used
Open-Button connection (N.O. Open)
Close-Button connection (N.O. Close)
Rubber edge connection (N.C.). If not used, leave jumped.
Connection of clock input (N.O.). If the contact connected is
open, the barrier closes and gets ready for normal operation.
If the contact is closed (N.C.), the barrier opens and remains
open until contact opening.
Photocell check input (PHOT FAULT) (see Fig. 3)
Electric edge check input (EDGE FAULT) (see Fig. 3)
Antenna input for radio-receiver (38 signal - 39 braid). Cable
RG58.
ENGLISH
~
for 1 minute
~
(1A max absorption)
~
3W max
11
LEO MV D - Ver. 04 -

Publicidad

Tabla de contenido
loading

Tabla de contenido