OPERATIONAL PROBLEMS
• Loss of oil between head and pump body
• The adjustment valve is reset with the
actioning lever at rest
• The machine does not provide any detergent
• The burner starts (ventilator is on), but the flame
is not lit
• The water temperature does not reach the required
level
• When the gun is closed the burner is on
• Excessive smoke
10. DISPOSAL
At the end of its useful life, you have to scrap and dispose of this product by taking it to a local differentiated waste collection center in conformity
to law.
Before scrapping, check the serial number plate on the machine: if it has the symbol
(Waste Electrical and Electronic Equipment, WAEE).
The user must inquire about the local electrical and electronic waste collection system and follow its instructions.
Illegal disposal of this product with normal domestic waste can seriously harm the environment and health and is subject to administrative penalties.
CAUSES
• Pump body side seal rings worn
• Loss in the spray gun
• Losses from the high pressure pipe or
from other parts of the hydraulic circuit
• Defective adjustment valve
• Detergent filter clogged
• Detergent tap closed
• Empty recipient
• No diesel oil is supplied
• Damaged diesel oil pump/motor coupling joint
• Dirty or ruined diesel oil nozzle
• Air in the diesel oil aspiration pipes
• Diesel oil solenoid valve not functioning
• Weak or absent ignition spark
• Dirty or badly adjusted ignition electrodes
• Lack of water in the hydraulic system
• Fuel supply is insufficient
• Diesel oil flow pressure is insufficient
• Broken thermostat
• The heating pipe coil is clogged with calcareous
deposits
• The pressure switch does not work
• Incorrect combustion
• Presence of impurities in the fuel
• Electrodes in incorrect position
• Incorrect air adjustment
• Dirty or worn diesel oil nozzle
• Dirty diesel oil pump and/or filter
• Broken solenoid valve
27
SOLUTIONS
• Replace the seal rings
• Replace the spray gun
• Check the status of the H.P. pipe and the
entire hydraulic circuit
• Disassemble the valve and clean or replace it
• Clean filter or replace it
• Open the tap or replace it
• Fill the recipient
• Check diesel oil level and, if necessary, fill the tank
• Clean and/or replace the diesel oil pump
• Clean and/or replace the diesel oil filter
• Replace the joint
• Clean the nozzle with the compressed air or with
the diesel oil and replace it
• Check all joints are tightly connected
• Clean and/or replace the solenoid valve
• Check the ignition transformer
• Check the electrodes and/or the ignition
transformer
• Clean and adjust the electrodes
• Check the hydraulic system
• Clean the diesel oil nozzle and/or the diesel oil
filter
• Calibrate the diesel oil pump or replace it
• Replace the thermostat or request the intervention
of the assistance centre
• Follow the instructions of the "Descaling"
paragraph
• Request the intervention of the assistance centre
• Request the intervention of the assistance centre
• Empty the tank and carefully clean it
• Request the intervention of the assistance centre
• Request the intervention of the assistance centre
• Clean or replace the nozzle
• Clean the diesel oil filter and/or the pump
• Replace the solenoid valve
, it means that disposal is regulated by EU Directive 2003/96