Descargar Imprimir esta página

BUTSIR ATALAYA Serie Manual De Instrucciones página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS
Lighting
Before igniting the appliance, perform "Leakage Testing" in a well-ventilated area (outdoor). At first use
and after every LPG cylinder substitution, appliance gas circuit must be purged of the inside air before
igniting! To do this, turn the control knob counter clockwise to the ignition position and push it holding
for 1 minute before attempting ignition.
1 - Make sure that LPG cylinder, full 4/5 its capacity, contains proper LPG Gas (refer to Technical Data on
page 2). Turn LPG cylinder valve in full "ON" position and close LPG compartment panel.
2 - Make sure that burner control knob is in "OFF" position (full disk).
3 - Push the control knob and keep pressing while turning counter-clockwise to the corresponding Maxi-
mum position (big flame). At the same time push the ignition button (star). Igniter will spark automa-
tically.
4 - When the burner is lit in Maximum position (big flame), stop pushing ignition button (star) and keep
the control knob pressed but not over 30 seconds to heat the thermocouple (FSD); then release it (first
ignition take generally more time, because gas circuit is full of air).
5 - If the burner does not keep lit, wait 5 minutes and then repeat steps 3 and 4.
6 - Burner now is lit in Maximum position (big flame).
7 - Adjust the heat input by turning the knob from the Maximum position (big flame), to the Minimum
position, as properly.
8 - After lighting, turn knob from Minimum to Maximum (big flame) position and back, to check flame
stability.
9 - In case of accidental break down of the flame (for wind or other reasons), FSD will shout-off gas supply
automatically (FSD = Flame Safety Device) not over 60 seconds.
Note: The burner may be noisy when initially turned on.
To eliminate excessive noise from the burner, turn the control knob to the Minimum position and back.
If you experience any ignition problem, consult the following "Troubleshooting".
To turn "OFF" the appliance
1. Turn appliance control knob clockwise up to "OFF" position.
2. Turn the LPG cylinder valve to the "OFF" position.
3. Allow the appliance to cool before moving it (at least 30 minutes).
Re-Lighting
1. Turn control knob to "OFF" position.
2. Wait at least 5 minutes, to let gas dissipate, before attempting burner re-light.
3. Repeat the "Lighting" steps.
Leakage testing
Never check for gas leakages with a flame or while smoking.
This appliance needs to be periodically checked for leakages and an immediate check is required if the
smell of gas is detected.