Make a soap solution using 1 part of liquid di-
sh-washing soap to 3 parts water. The soap so-
lution can be applied with a soap bottle, brush,
or rag to the leakage tested points shown in the
figure beside.
The valve of the LPG cylinder should be in the
"OFF" position at this point of the leakage test.
Once the soapy solution is applied to the gas
connections, the valve of the LPG cylinder needs
to be turned to the "ON" position.
Soap bubbles will begin to form in the soapy so-
lution if any leakage is present.
In the event of gas leakage, the appliance shall
not be used or if alight, the gas supply shall be
shut-off and the appliance shall be investigated
and rectified before it is used again. Tighten any
leaking fittings, then turn on gas supply and re-
check.
If necessary, substitute gasket (according to EN
549 Class B2) or material used to guarantee tight-
ness (according to EN 751-1 Class I).
GAS REQUIREMENTS
Use only the type of gas and the type of LPG cylinder specified by the manufacturer.
●
Appliance must use an approved gas regulator according to the EN Standard EN16129 and flexible gas
●
rubber pipe according to applicable EN-standard with a length not over 1.5 m. When substitution will be
necessary, you must purchase suitable gas regulator, flexible gas rubber pipe and clamps from your local
gas dealer; gas regulator should be substituted not over 10 years.
Flexible gas rubber pipe must be in the LPG compartment carefully, avoiding any twisting.
●
Never use a damaged gas regulator.
●
Never connect this appliance to an unregulated LPG source (gas regulator is mandatory to be used).
●
When the appliance is not in use, turn the LPG cylinder in "OFF" position.
●
Always perform a leakage test on gas connections whenever a LPG cylinder is connected. If bubbles form
●
in the leakage test solution, do not use it. Never use a flame to test for leakages. It is strictly forbidden
and dangerous!.
LPG CYLINDER
LPG cylinder used must be in accordance with the National Rules in force.
●
Refer to your gas supplier for instructions how to use and handle LPG cylinder.
●
Never use an LPG cylinder with a damaged body or valve.
●
Change LPG cylinders in an amply ventilated area, away from any ignition source (candle, cigarettes and
●
so on).
If appliance is stored indoors, detach and leave LPG cylinder outdoors in a ventilated and protected area.
●
LPG cylinder must always be used in an upright position.
●
Do not store a spare or disconnected LPG cylinder near this appliance.
●
Manual ATALAYA.indd 19
LeakageTest
Point
➀➁➂➃
10/7/19 9:43
19