TECHNICAL DATA
Definition in accordance with
Constructive system
Global thermal power in kW
Nominal thermal power in kW
Power given back to water in kW
Power given back to the room in kW
Hourly consumption in kg / h (wood with 20% humidity)
Efficiency in %
CO measured at 13% oxygen in %
Smoke outlet diameter in mm
Chimney height - dimension in mm
Fluid contents of the exchanger in L (litres)
Chimney draught in Pa (mm H
boiler connections (Ø)
Automatic discharge pipe diameter (Ø)
Exhaust gas emission in g/s
Exhaust gas temperature in °C
Average temperature of exhaust fumes in °C - EN13240
Optimal working temperature in °C
Max. working pressure in bar
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Food warmer size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
(30 kcal/h x m
3
(*) 200 mm diameter can be used with flue of no less than 6 m.
(**) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of prFood warmer efficiency.
(***) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
product is: favourable type of building (30 kcal/h x m
x m
).
3
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
IMPORTANT: THE POWER OF THE CONNECTED HEATING SYSTEM MUST BE PROPORTIONAL TO THE POWER TRANSFERRED TO THE WATER
BY THE THERMOPRODUCT; A CHARGE WHICH IS TOO LOW DOES NOT ALLOW REGULAR FOOD WARMER OPERATION, WHILE A CHARGE
WHICH IS TOO HIGH PREVENTS ADEQUATE RADIATOR HEATING.
THE DECLARED TECHNICAL DATA HAVE BEEN ACHIEVED BY BURNING BEECH WOOD CLASS "A1" ACCORDING TO THE REQUIREMENT UNI EN ISO
17225-5 AND WOOD MOISTURE CONTENT LESS THAN 20%. BY BURNING A DIFFERENT KIND OF WOOD THE EFFICIENCY OF THE PRODUCT ITSELF
COULD CHANGE AND SOME SPECIFIC ADJUSTMENTS ON THE APPLIANCE COULD BE NEEDED.
12
O)
2
)
3
); less favourable type of building (40 kcal/h x m
3
TERMOROSA DSA 4.0
(*) (**) 5m – 220x220 Ø220
Chapter FIRE PREVENTION SAFETY
ENGLISH
EN 13240
1
12,4
11,0
7,0
4,0
3,0
88,6
0,052 - (649 mg/m
)
3
150 S/P
12
12 (1.2)
1 "F gas
½"M gas
8,2
172
205,2
70-75
VEA 1,5 bar - VEC 3 bar
220 x 200
256 x 270 x 400
330 x 300 x 410
Movable - flat
855
1030
664
286
315 (***)
); unfavourable type of building (50 kcal/h
3