with pressurized air. At the same time, in the
test, it can be more intuitive to observe the
spray ability of the injectors.
1) Install the quick male to the air inlet on the
top of the device. See following:
2) Select system function, and then select pa-
rameter setting. Change the parameter value
of WORK WITH AIR to Y and save it.
3) When you do the test, please connect
the compressed air. The air pressure into the
machine should be adjust to 4~6bar (EFI) or
6~8bar (GDI). If the air pressure is lower than
3bar, this mode will not work.
4) If you do test with air, please set the test fuel
pressure slightly higher than the air pressure.
About higher 0.5bar.
Warning: Don't set the fuel pressure lower
than the air pressure!
5.4 Tidy up after operating
Tidy-up should be done after cleaning and
testing is completed:
1) Press "Drain" icon to drain the test liquid into
fuel tank.
2) Switch off the power and unplug from the
socket.
3) Clean the Injector Cleaner & Tester control
panel with soft cloth.
4) Drain the test liquid from the tank into a
container to avoid volatilization. Store the test
liquid in a safe place if it can be used again, or
dispose of it in accordance with relevant regu-
lations if it is too dirty.
6. OPERATION
6.1 First power on
Please set your language.
The fuel tank is empty and fill enough test fluid
into it.
· 24 ·
REF.54392