Full Programming Options
Quickstart
>
Tel. Numbers >
Alarm no. 1
Alarm no. 2
Alarm no. 3
Alarm no. 4
Tech.no.
Background no.
Call attempts
Settings >
Codice ID
Volume
Accessories >
System Config >
System Config+ >
HW Monitoring >
Lift Monitor
IP1 only
IP1+IP2 (Serv.)
Service Count
Interval
Live Count
Delays
>
COP delay
MPS delay
TOC delay
Tech IP1 delay
Tech IP2 delay
Hangup delay
Answer delay
Messages
>
Location
Reassurance
Guidance
Time / Date >
Time
Date
Advanced
>
Passcode
Network ID
Next EN81 call
PBX Frequency
Language
Relay Mode
Relay Override >
HW Config >
GMT Offset
DTMF RX
Menu Sections continued...
Advanced Settings continued...
Relay Mode
The relay contact on a Memcom
supply to an external device. The following modes are available:
Relay Mode >
>
>
can be used to switch the power
+
Siren
û
Relay contacts close when the Alarm Push
is activated, and open again after the alarm
push delay. Typically used to trigger a siren
on the lift car.
Door (NO/CMD)
û
Door release mode, release on command,
default relay state is N/O: The door release is
only activated if the operator presses the '8'
key on their handset during the initial alarm
call or any follow-up calls. The release will
then remain activated until the call ends.
Door (NC/CMD)
û
Door release mode, release on command,
default relay state is N/C: The door release is
only activated if the operator presses the '8'
key on their handset during the initial alarm
call or any follow-up calls. The release will
then remain activated until the call ends.
Door (NO/ALM)
û
Door release mode, release on alarm push,
default relay state is N/O. The door release
is activated as soon as the Alarm Pictogram
is lit, and remains activated until the End of
Alarm signal is received.
Door (NC/ALM)
û
Door release mode, release on alarm push,
default relay state is N/C. The door release
is activated as soon as the Alarm Pictogram
is lit, and remains activated until the End of
Alarm signal is received.
PSTN fault
û
The relay contacts default to closed, and
open whenever a PSTN line fault is detected.
When the fault condition is cleared, the
contacts return to the default closed state.
GSM fault
The relay contacts default to closed, and
open whenever a GSM fault is detected.
When the fault condition is cleared, the
contacts return to the default closed state.
Note: GSM monitoring must first be setup
under 'HW monitoring.
Tech. fault
û
Technical fault mode - The relay contacts
default
whenever any technical fault is detected by
the Memcom
cleared, the contacts close again.
Emg. Lighting
û
Emergency lighting mode - the relay contacts
default to the open state, closing within
1 second of a loss of external power. This
allows the use of the relay to switch backup
power to emergency lighting hardware
during an external power failure. Once
external power is restored, the relay contacts
open again.
Spk. Picto
û
If a dual illuminated alarm push is connected
to the relay contacts:
When the call centre answers an alarm call
the relay contact will close and trigger the
illumination on the alarm push; alarm push
will remain lit until the call centre ends the
call.
Both Picto
ü
If a dual illuminated alarm push is connected
to the relay contacts:
When the alarm button is pressed the relay
contact will close triggering the illumination
on the alarm push; alarm push will remain lit
until the call centre ends the call.
to
the
closed
state,
opening
. Once the fault condition has
+
11