Memco Memcom+ Guia De Instalacion página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
Full Programming Options
Quickstart
>
Tel. Numbers >
Alarm no. 1
Alarm no. 2
Alarm no. 3
Alarm no. 4
Tech.no.
Background no.
Call attempts
Settings >
Codice ID
Volume
Accessories >
System Config >
System Config+ >
HW Monitoring >
Lift Monitor >
IP1 only
IP1+IP2 (Serv.)
Service Count >
Interval
Live Count
Delays >
COP delay
MPS delay
TOC delay
Tech IP1 delay
Tech IP2 delay
Hangup delay
Answer delay
Messages >
Location
Reassurance
Guidance
Time / Date >
Time
Date
Advanced >
Passcode
Network ID
Next EN81 call
PBX Frequency
Language
Relay Mode
Relay Override >
HW Config >
GMT Offset
DTMF RX
Menu Sections continued...
Lift Monitor
The lift monitor section allows you to detect faults from third party
lift monitoring devices connected to the technical inputs on the
Memcom
unit. When a fault is detected the Memcom
+
and place a technical alert. There are two options for technical
inputs:
IP1 only – As default this input is always active, so does not
need programming. If a third party device is connected to the
Memcom
immediately when a fault is indicated by the third party device.
IP1 + IP2 (Serv.) – Selecting this option allows customers to use
the service counter (connections 16 and 17) input as a second
technical input.
Service Count
Memcom
+
can be connected to the lift controller (connections 16
and 17) to track the number of operations the lift performs.
The Memcom
after a set number of operations (intervals). The Technical Alert will
be placed with the event message "Technical Alarm – Lift in service
too long". This can then be used to determine when a lift may need
to be serviced.
Service Count >
Delays
The delays can be set to alter the length of the delay before the
unit places a call.
COP delay - How long (in seconds) each of the alarm buttons,
in the COP, needs to be pressed before an emergency call is
placed. Default is 3 seconds
MPS delay - 'MPS' refers to Multi Point Station accessories
(part number 492 021). How long (in seconds) each of the alarm
buttons, on the MPS units, needs to be pressed before an
emergency call is placed. Default is 3 seconds.
TOC delays - how long (in seconds) the alarm button, in the
Memcom
emergency call is placed. Default is 3 seconds.
Tech IP1 delay - The delay before a technical call is placed,
upon receiving a fault signal from a connected third party device
using the Technical Input.
Tech IP2 delay - The delay before a technical call is placed,
upon receiving a fault signal from a connected third party device
using the Technical Input.
>
Hang up delay - sets time (in minutes) before Memcom
>
up a call (talk time).
Answer delay - the number of rings the Memcom
before answering any incoming calls.
Where multiple Memcom
the same Answer Delay set.
+
unit (connections 11 and 12), the unit will dial out
can then be programmed to place a Technical Alert
+
Interval
Live Count
+
unit (Top Of Car), needs to be pressed before an
are sharing a line, they must all have
+
will dial out
+
Set the number of operations you want
the lift to perform before a Technical
Alert is placed by the Memcom
+
This shows a live count of the operations
that the lift has performed since
the controller was connected to the
Memcom
.
+
hangs
+
must detect
+
9

Publicidad

Tabla de contenido
loading

Tabla de contenido