FUNCTION « FABRIC TENSION » FOR PRODUCT WITH LOCKING SYSTEM (MANUAL OR AUTOMATIC SETTING)
8
This function is used to adjust the fabric tension (Locks) of the product with 3 possible threshold levels (low-medium-high).
1
+
1 - Run the product to the halfway position using the DOWN or UP button. Then press the STOP button to
stop the product.
2 - To activate this function press twice successively:
- For half a second press simultaneously "STOP" and "DOWN" buttons, and release. (no jog)
- For more than 3 s press simultaneously "STOP" and "DOWN" buttons, until the motor jogs.
The motor is now in programming mode for only 10 seconds, the motor is factory set at the medium level.
3 - To increase the tension on the fabric, press the "UP" button until the motor makes a jog, the fabric
tension is now set to the upper threshold.
- To decrease the tension on the fabric, press the "DOWN" button until the motor makes a jog, the fabric
tension is now set to the lower threshold.
4 - Confirm the new setting by pressing 2 seconds the "STOP" button, until the motor jogs. The new tension
level is memorized.
OBSTACLE DETECTION: DEACTIVATION/ ACTIVATION
9
This function give the possibility to activate or deactivate the obstacle detection during the downward
mouvement in case of untimely stops.
1
+
1 - Run the product to the halfway position using the DOWN or UP button. Then press the STOP button to
stop the product.
2 - To activate this function press twice successively:
- For half a second press simultaneously "STOP" and "UP" buttons, and release. (no jog)
- For more than 3 s press simultaneously "STOP" and "UP" buttons, until the motor jogs.
The motor is now in programming mode for only 10 seconds. The obstacle detection is activated in the
factory mode.
3 - To deactivate the obstacle detection, press the "UP" button until the motor jogs (See drawing above).
- To activate the obstacle detection, press the "DOWN" button until the motor jogs (See drawing above).
4 - Confirm the new setting by pressing 2 s the "STOP" button, until the motor jogs. The new setting is
memorized.
EN
8/12
2
+
3 s
2 s max.
2
+
3 s
2 s max.
3
low
medium
=>
3
Activated Deactivated
=>
4
high
2 s
4
2 s