13.2 Clean the product with compressed air
ATTENTION
Product damage due to use of a compressed air device
with too high of a pressure
By cleaning the product with highly compressed air,
electrical components may become damaged.
-
Use a compressed air device with a low pressure
of max. 2 bar.
1.
Always keep enough distance to the product.
2.
Remove dirt with a compressed air device
(max. 2 bar).
13.3 Cleaning the chip extraction system
A chip extraction system is not included in the scope of
delivery. Follow the manufacturer's operating instruc-
tions to properly clean the extraction system.
14. Transport
m WARNING
Danger of injury due to unexpected start-up of the ma-
chine
-
Remove the mains plug from the socket.
14.1 General notes
• Only lift the product by the machine housing.
• Package the product to prevent transport damage.
Use the original packaging.
• Protect the product from vibrations and shocks, in
particular during vehicular transport.
• Ensure adequate load securing when transporting
in a vehicle.
14.2 Product-specific notes
m WARNING
Danger of injury due to excessive product weight.
-
Ask a second person to help you mounting the
product.
1.
When lifting the product, note its weight see tech-
nical data.
2.
Always switch off the power tool before transport
and disconnect it from the power supply.
3.
Always carry the power tool with at least one oth-
er person, do not carry by the table extensions.
To transport the power tool, lift it by the machine
housing.
4.
Protect the power tool from impacts, shocks and
severe vibrations, e.g. during vehicular transport.
5.
Secure the power tool against toppling and slip-
ping.
6.
Never use protective devices for handling or trans-
port.
14.3 Using a machine stand to transport the device
(fig. 37)
• Lift the device by the machine stand as shown in fig.
37.
• Move the device to the desired location.
14.4 Folding the machine stand in and out (fig. 37)
• To fold the machine stand (24) in, loosen the locking
handle (14) and fold the machine stand (24) in.
• To fold out the machine stand (24), lift the machine
and ensure that the locking latch (14) engages.
15. Maintenance
m WARNING
Danger of injury due to unexpected start-up of the ma-
chine
-
Remove the mains plug from the socket.
m WARNING
Warning against unexpected hazards and damages to
the product
-
Never carry out unauthorized changes or repairs
to the product that are not described in the oper-
ating manual.
-
Do not carry out work on the product described
for a specialist workshop.
15.1 General notes
• Check the product for loose, worn or damaged com-
ponents.
• Check the nuts, pins and screws for firm seating.
• Check the covers and protective equipment for dam-
age and correct seating.
• Check the electrical connections. Repairs to the
electrical connections may only be carried out by a
specialist workshop.
15.2 Oiling the product
1.
Oil the rotating parts once monthly to extend the
life of the tool.
2.
Do not oil the motor.
www.scheppach.com