7. Maintenance and Cleaning
This chapter describes the user maintenance and cleaning procedure for the Stratos 300. Only those tasks that
can be carried out by qualified dental lab experts are listed. All other tasks must be performed by qualified
service personnel at a certified Ivoclar Service Center.
7.1
Monitoring and maintenance
The time for these maintenance procedures depends on the frequency of use and the working habits of the
user. For these reasons, the recommended times are only approximates.
What
Check centric rubber band for damage and cracks and
replace, if necessary.
Check if knurled screws are dirty.
Check if joint bolt is sufficiently lubricated.
Check if incline support holder and holding device are dirty. Holding device for incline
Important!
In order to protect the movable joint parts from
wear, use the enclosed silicone grease to lubricate
them from time to time.
7.2
Cleaning
What
Knurled screws contaminated with wax or plaster
Joint bolt contaminated with dust
Protect the Stratos 300 from acids and solvents (e.g. MMA) to prevent the finish from being damaged.
18
Part
Centric rubber band
Knurled screw
Joint bolt
support holder
Frequency
Weekly or as necessary
Weekly or as necessary
Frequency
Monthly or as necessary
Weekly
Monthly or as necessary
Weekly or as necessary
Cleaning agent/Measure
Rinse with warm water
Rinse with warm water