n Enkele buitenunit
Model met
Nominale
Spanningsbereik
warmtepomp
spanning
Min
Max
MMY-
(V-Ph-Hz)
MAP0501HT7
380-3-60
342
MAP0601HT7
380-3-60
342
MAP0801HT7
380-3-60
342
MAP1001HT7
380-3-60
342
MAP1201HT7
380-3-60
342
n Combinatie van buitenunits
Model met
Nominale
Spanningsbereik
warmtepomp
spanning
MMY-
(V-Ph-Hz)
Min
Max
AP1401HT7
380-3-60
342
418
AP1601HT7
380-3-60
342
418
AP1801HT7
380-3-60
342
418
AP2001HT7
380-3-60
342
418
AP2201HT7
380-3-60
342
418
AP2211HT7
380-3-60
342
418
AP2401HT7
380-3-60
342
418
AP2411HT7
380-3-60
342
418
AP2601HT7
380-3-60
342
418
AP2801HT7
380-3-60
342
418
AP3001HT7
380-3-60
342
418
AP3201HT7
380-3-60
342
418
AP3211HT7
380-3-60
342
418
AP3401HT7
380-3-60
342
418
AP3411HT7
380-3-60
342
418
AP3601HT7
380-3-60
342
418
AP3611HT7
380-3-60
342
418
AP3801HT7
380-3-60
342
418
AP4001HT7
380-3-60
342
418
AP4201HT7
380-3-60
342
418
AP4401HT7
380-3-60
342
418
AP4601HT7
380-3-60
342
418
AP4801HT7
380-3-60
342
418
Legenda
MCA
: Minimum Circuit Amps (max. stroomsterkte circuit)
MOCP
: Max. stroomsterktebescherming (Amps)
ICF
: Maximum Instantaneous Current Flow Start (max. startstroom)
RLA
: Rated Load Amps (toeg. lasttstroomsterkte)
RLA
LRA
418
4.2 + 4.2
418
4.8 + 4.8
418
5.4 + 5.4
418
6.9 + 6.9
418
10.0 + 10.0
Unit nr.1
Unit nr.2
RLA
LRA
RLA
5.4 + 5.4
—
4.8 + 4.8
5.4 + 5.2
—
5.4 + 5.4
6.9 + 6.9
—
5.4 + 5.4
6.9 + 6.9
—
6.9 + 6.9
5.4 + 5.4
—
5.4 + 5.4
10.0 + 10.0
—
6.9 + 6.9
5.4 + 5.4
—
5.4 + 5.4
10.0 + 10.0
—
10.0 + 10.0
6.9 + 6.9
—
5.4 + 5.4
6.9 + 6.9
—
6.9 + 6.9
6.9 + 6.9
—
6.9 + 6.9
5.4 + 5.4
—
5.4 + 5.4
10.0 + 10.0
—
6.9 + 6.9
6.9 + 6.9
—
5.4 + 5.4
10.0 + 10.0
—
10.0 + 10.0
6.9 + 6.9
—
6.9 + 6.9
10.0 + 10.0
—
10.0 + 10.0
6.9 + 6.9
—
6.9 + 9.9
6.9 + 6.9
—
6.9 + 6.9
10.0 + 10.0
—
6.9 + 6.9
10.0 + 10.0
—
10.0 + 10.0
10.0 + 10.0
—
10.0 + 10.0
10.0 + 10.0
—
10.0 + 10.0
Compressor
Compressor
Unit nr.3
Unit nr.4
LRA
RLA
LRA
RLA
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
4.8 + 4.8
—
—
—
—
—
—
—
5.4 + 5.4
—
—
—
—
—
—
—
5.4 + 5.4
—
—
—
5.4 + 5.4
—
—
—
6.9 + 6.9
—
—
—
5.4 + 5.4
—
5.4 + 5.4
—
6.9 + 6.9
—
—
—
5.4 + 5.4
—
5.4 + 5.4
—
6.9 + 6.9
—
—
—
5.4 + 5.4
—
5.4 + 5.4
—
10.0 + 10.0
—
—
—
6.9 + 6.9
—
5.4 + 5.4
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
6.9 + 6.9
—
10.0 + 10.0
—
6.9 + 6.9
—
10.0 + 10.0
—
10.0 + 10.0
LRA
: Locked Rotor Amps (vaste rotor amp)
FLA
: Full Load Amps (volle last amp)
kW
: Nominaal uitgangsvermogen ventilatormotor (kW)
Ventilatormotor
kW
FLA
MCA MOCP
0.60
0.8
16.5
0.60
0.8
16.5
0.60
1.0
20.0
0.60
1.1
22.5
0.60
1.1
24.5
Ventilatormotor
LRA
kW
FLA
MCA MOCP
—
0.6 × 2 1.0 + 0.8
36.5
—
0.6 × 2 1.0 + 1.0
40.0
—
0.6 × 2 1.0 + 1.1
42.5
—
0.6 × 2 1.1 + 1.1
45.0
—
0.6 × 3 1.0 + 1.0 + 0.8
56.5
—
0.6 × 2 1.1 + 1.1
47.0
—
0.6 × 3 1.0 + 1.0 + 1.0
60.0
—
0.6 × 2 1.1 + 1.1
49.0
—
0.6 × 3 1.1 + 1.1 + 1.0
62.5
—
0.6 × 3 1.1 + 1.1 + 1.0
65.0
—
0.6 × 3 1.1 + 1.1 + 1.1
67.5
—
0.6 × 4 1.0 + 1.0 + 1.0 + 1.0
80.0
—
0.6 × 3 1.1 + 1.1 + 1.1
69.5
—
0.6 × 4 1.1 + 1.0 + 1.0 + 1.0
82.5
—
0.6 × 3 1.1 + 1.1 + 1.1
71.5
—
0.6 × 4 1.1 + 1.1 + 1.0 + 1.0
85.0
—
0.6 × 3 1.1 + 1.1 + 1.1
73.5
—
0.6 × 4 1.1 + 1.1 + 1.1 + 1.0
87.5
—
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
90.0
—
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
92.0
—
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
94.0
—
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
96.0
—
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
98.0
OPMERKING :
RLA is gebaseerd op de volgende omstandigheden.
Binnentemperatuur
: 27°C DB/19°C WB
buitentemperatuur
: 35°C DB
60Hz
Voeding
ICF
20
—
20
—
30
—
30
—
30
—
Voeding
ICF
40
—
50
—
50
—
60
—
70
—
60
—
70
—
60
—
70
—
80
—
80
—
90
—
80
—
100
—
80
—
100
—
90
—
100
—
100
—
110
—
110
—
110
—
110
—