Program Customizing - Orbis Thermo X Manual De Uso

Cronotermostato digital
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROGRAM CUSTOMIZING

This procedure changes the temperature profi le (hourly schedule) to suit special
requirements, assigning the desired temperature to each of the 24 hour segments.
Every hour of the day can be associated 1 of the three available temperatures (T0,
T1, T2).
When in SUMMER-AIR CONDITIONING MODE, temperature T0 equals system OFF
A temperature change delay of 15, 30 or 45 minutes can be set for every hour.
Both WINTER-HEATING programs and SUMMER-AIR CONDITIONING programs
can be customized independently.
For example, program P1 for WINTER-HEATING, can feature totally different hours
and temperatures from the P1 program for SUMMER-AIR CONDITIONING.
1. Press
: the following reading will appear
2. Press
or
to select the hourly program that best meets the specifi c requirements
3. Press
: the current time will appear (minutes will be zeroed) and the associated
"small squares" will fl ash;
4. Press
or
to move to the hour segment whose assigned temperature needs to be
modifi ed
5. If you wish to delay the temperature change by 15, 30 or 45 minutes, press the key
below once, twice or three times
6. Press
,
or
Temperature T0: no small square
Temperature T1: 1 small square
Temperature T2: 2 small squares on top of each other
7. Repeat the steps from 4 to 6 for all the hour segments whose associated temperature
needs to be changed
8. Press
to store the changes and make the customized hourly program available.
9. If you wish to alter another program, repeat the steps from 2 to 8.
10. Press
or
to select the hourly schedule to be assigned to Monday (cfr. page 76
for Winter-Heating, or page 77 for Summer-Air conditioning)
11. Press
confi rm; the day of the week will change
12. Repeat steps 10 and 11 to select the hourly schedule to be assigned to the remaining
days of the week
13. After the Sunday schedule is confi rmed the device exits the programming and
resumes normal operation
to select the temperature to be assigned to the hour segment
- 74 -