T0, T1 AND T2 temperatures correspond to the values that will be kept when
in automatic operation mode, following the selected schedule and program
(temperature profi le).
• Press
to set temperature T0 (no "small square")
for WINTER-HEATING mode
for SUMMER-AIR CONDITIONING
• Press
to set temperature T1 (one "small square")
for WINTER-HEATING mode
for SUMMER-AIR CONDITIONING mode
• Press
to set temperature T2 (two "small squares")
for WINTER-HEATING mode
for SUMMER-AIR CONDITIONING mode
• Press
to confi rm or else wait for 45 seconds
min = +2.0°C; max = T1
mode system off
(the display will read "---")
min = T0; max = T2
min = +10°C; max = T2
min = T1; max = +35.0°C
min = T1; max = +35.0°C
- 75 -
User Manual - Thermo X