Diode Testing; Continuity Testing - Benning MM 5-1 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
Measuring
OL indication
range
6 A
10 A
*
Measuring range from ≥ 20 mA
7.5 Resistance ranges
Overload protection: 600 V
Measuring range OL indication
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
*
Measured values > 10 MΩ might cause changing values on the display
(max. ± 50 digits).

7.6 Diode testing

Overload protection: 600 V
Max. no-load voltage: 1.8 V
Measuring range OL indication
1.500 V

7.7 Continuity testing

Overload protection: 600 V
The built-in buzzer sounds in the case of a resistance R less than 30 Ω up
to 200 Ω. For a resistance R higher than 200 Ω, the buzzer does not emit an
acoustic signal.
Measuring range OL indication
600.0 Ω
7.8 Capacity ranges
Conditions: capacitors discharged and connected in accordance with the polar-
ity stated.
Overload protection: 600 V
Measuring range OL indication
50.00 nF
500.0 nF
5.000 µF
50.00 µF
500.0 µF
1000 µF
7.9 Frequency ranges
Overload protection: 600 V
Measuring range
100.00 Hz
1000.0 Hz
10.000 kHz
50.00 kHz
Minimum frequency: 10 Hz
Minimum sensitivity: > 4 V
10/ 2015
Resolution
6.600 A
0.001 A
20.00 A
0.01 A
AC/ DC
Resolution
660.0 Ω
6.600 kΩ
0.001 kΩ
66.00 kΩ
0.01 kΩ
660.0 kΩ
6.000 MΩ
0.001 MΩ
40.00 MΩ
0.01 MΩ
AC/ DC
Resolution
1.550 V
0.001 V
AC/ DC
Resolution
660.0 Ω
AC/ DC
Resolution
55.00 nF
0.01 nF
550.0 nF
5.500 µF
0.001 µF
55.00 µF
0.01 µF
550.0 µF
1100 µF
AC/ DC
OL indication
Resolution
100.00 Hz
1000.0 Hz
10.000 kHz
0.001 kHz
50.00 kHz
for V
eff
AC
> 20 V
for V
eff
> 0,6 A
for A
eff
BENNING MM 5-1/ 5-2
in frequency range 45 Hz - 500 Hz (sine)
± (1.5 % of reading + 5 digits)*
± (1.5 % of reading + 5 digits)
0.1 Ω
± (0.5 % of reading + 5 digits)
± (0.5 % of reading + 2 digits)
± (0.5 % of reading + 2 digits)
0.1 kΩ
± (0.5 % of reading + 2 digits)
± (0.5 % of reading + 2 digits)
± (1.0 % of reading + 5 digits)*
± (1.0 % of reading + 3 digits)
0.1 Ω
± (0.5 % of reading + 5 digits)
± (2.0 % of reading + 10 digits)
0.1 nF
± (2.0 % of reading + 5 digits)
± (2.0 % of reading + 5 digits)
± (2.0 % of reading + 5 digits)
0.1 µF
± (2.0 % of reading + 5 digits)
1 µF
± (2.0 % of reading + 5 digits)
0.01 Hz
± (0.2 % of reading + 2 digits)
0.1 Hz
± (0.2 % of reading + 2 digits)
± (0.2 % of reading + 2 digits)
0.01 kHz
± (0.2 % of reading + 2 digits)
(10 Hz - 10 kHz)
(10 kHz - 50 kHz)
AC
(10 Hz - 50 kHz)
AC
Measurement accuracy
Measurement accuracy
Measurement accuracy
Measurement accuracy
Measurement accuracy
Measurement accuracy
24

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mm 5-2Mm 6-1Mm 6-2