DIP-SWITCH 8 ON = Release Stroke Enabled
DIP-SWITCH 8 OFF = Release Stroke Disabled
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
MASTER / SLAVE
The control unit can be set to MASTER or SLAVE operation. This allows
possible connection of the line of BUS accessories to a control unit set as
SLAVE for automations that envisage the use of systems that must work in
synchronous mode (e.g. double barriers).
1
2
3
4
5
6
O
N
DIP-SWITCH 9 ON = Slave Control Unit
DIP-SWITCH 9 OFF = Master Control Unit
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
NOTE: In applications requiring the use of a single control unit, make sure it is
always set as MASTER. Otherwise, the automation will not work.
1
2
3
4
5
6
7
8
9
10
DISABLING THE DS (SAFETY DEVICES)
Is it possible to disable the DS (Safety Devices) installed and connected
to the BUS line accessories, such as the photocells and the 8K2 input.
This allows to operate the automation even in cases of suspected faults
to the DS, facilitating maintenance or technical checks of the system. In
any case, if the DS are disabled, only those that are actually faulty will be
excluded from the BUS, along with input 8K2, while the functional DS will
remain enabled.
1
2
3
4
5
6
7
8
9
10
30
COMUNELLO ®Copyright 2015 - All right reserved
7
8
9
10
7
8
9
10
O
1
2
3
4
5
6
7
8
N
DIP-SWITCH 10 ON = DS Disabled
DIP-SWITCH 10 OFF = DS Enabled
NOTE: Always enable the DSs, if present. Temporarily disable them only
during maintenance.
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
8K2 INPUT (LOCK)
The control unit has a dedicated terminal for the safety devices (DS) with an
8K2 impedance threshold. This input blocks (STOP) the automation if the
connected impedance has a value of 8K2 Ohm (±20%):
Input terminals for DS (Safety Devices) 8K2.
8K2
Input to 8K2 Ohm impedance threshold
GND
Common
ANTENNA INPUT
The control unit has a dedicated terminal to connect the radio antenna
needed to receive commands from the 433 MHz radio transmitters
(antenna impedance: 50 Ohm).
Input terminals for DS (Safety Devices) 8K2.
8K2
Input to 8K2 Ohm impedance threshold
GND
Common
STROKE PROGRAMMING (AUTOSET)
The control unit allows Automatic Programming of the maximum gate
stroke.
CHECKING OPERATOR DIRECTION OF ROTATION:
To accelerate the system's configuration for the stroke movement, it is
advisable to check the direction of rotation of the operators (Operator
1 and Operator 2) and whether they are consistent with the expected
movement of the gate. Also check the opening priority between Operator
1 and Operator 2 (which operator must open first). If the operators move
contrary to what expected, press the RESET button, stopping the operators
and change the direction of rotation or priority to the operator you want to
start first, without intervening physically on the electrical connections (par.
CHANGING ROTATION DIRECTION AND START PRIORITY).
STROKE PROGRAMMING:
To start the auto-learning cycle, position the half-open gate, press the
AUTOSET button until the respective LED lights up (positioned above the
AUTOSET button) and release the button. The AUTOSET led starts to flash
for a few seconds (detection of any accessories connected to the BUS
line), after which the led remains lit and the operators start the movement.
Operator 2 will close the gate until it reaches the limit switch or limit stop,
after which Operator 1 will repeat the movement.
The control unit completes the Self-learning phase by performing a
complete opening and closing cycle (turning off the AUTOSET led).