Connect the operator to the control board
VIVO- M201(M)
PUL2
PUL1
FCA2 COM FCC2
SCA
P1 P2 P3
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
P22 P23
24Vac
ST1
FT1
ST2
FT2
FCA1
FCC1
STOP
LOCK
1
Motor connection (common)
2
Motor connection (Turn 1)
3
Motor connection (Turn 2)
4
Earth
Since this is a stationary unit for
permanent connection, an external cut-
off must be fitted.
Position the cover and tighten the gland
G4
G5
G6
G1
G2
G3
G7 G8
G9 G10
N
L
POWER
Courtesy
Lamp.
MOTOR2 (G2-G1-COM)
MOTOR1 (G2-G1-COM)
Light
N L
VIVO- M201:
230Vac/ 50Hz
VIVO- M201M:
125Vac/ 60Hz
A1
P240W
P240U
Before making any electrical connections,
check the control board instructions manual.
We recommend using the VIVO-M101(M) or VIVO-
M201(M) control boards.
The connection of an operator in the VIVO-
M201(M) control board is shown as an example. If a
single operator is used, use cable connectors G1, G2
and G3.
1 Connect the operator to the control board using
cable connectors G1, G2 and G3.
2 Connect the capacitor (C) to cable connectors G1
and G2.
3 Connect the control board to the electricity supply.
4 Activate the power supply switch.
Before carrying out any gate movement,
ensure there is no person or object in the radius
of action of the gate and the drive mechanisms.
5 Use the PUL1-PUL2 control board mini-pushbuttons
(CLOSE-OPEN) to check the motor connections are
correct (turning direction).
If
the
turning
direction
interchange cables 2 and 3.
Ensure the earth cable is properly connected.
1 Position the cover (1) in its housing (2) and secure
with the screws (3).
2 Tighten the gland (4) to ensure the electrical cable
input (5) is seal tight.