Descargar Imprimir esta página

sangiorgio F4 ADVANCE Manual De Operación Y Mantenimiento página 131

Publicidad

Idiomas disponibles

Idiomas disponibles

EMPTYING PROCEDURE
1) Place a tray between the cabinet and the
end of the fi lter.
Figure 18
!
Warning! After a wash cycle
with high temperature, wait until it is
cooled down. Danger of burning.
2) Loosen the fi lter using the appropriate
holder in order to let the water fl ow.
Figure 19
When there is no more water coming out,
unscrew the fi lter completely and clean it
carefully. Remove any foreign objects from the
fi lter.
28
Figure 20
Reinsert the drain fi lter and tighten it fi rmly
until it locks.
!
Warning! If you do not rein-
sert the fi lter or you do not screw it
until it is blocked, the water will come
out of the machine.
CLEANING OF ELECTRO-VALVE AND
WATER SUPPLY HOSE FILTERS
To clean the fi lters follow the instructions
below:
• Turn off the washing machine and
disconnect the power cable.
• Close the water and disconnect the
water supply inlet hose from the water
tap and from the washing machine.
• Get pair of tweezers and a tooth brush.
• Remove the fi lters from their place
(fi gure 21)
• Clean the fi lters with running water
making use of the tooth brush.
WATER LOADING TEST
1. Get a stopwatch;
2. Turn the programme knob to drain and
let it run for about two minutes;
3. Turn the programme knob to cotton
programme simultaneously start the
programme and the stopwatch;
4. From the moment the washing machine

Publicidad