Rockwell Automation ArmorStart 280 Manual Del Usuario página 183

Controlador distribuido de motores
Tabla de contenido

Publicidad

DeviceLogix
1 Hdw Inputs
10 Autobaud Enable
2 Network Inputs
11 Consumed IO Assy
3 Network Outputs
12 Produced IO Assy
4 Trip Status
13 Prod Assy Word 0
5 Starter Status
14 Prod Assy Word 1
6 DNet Status
15 Prod Assy Word 2
7 Starter Command
16 Prod Assy Word 3
8 Network Override
17 Consumed IO Size
9 Comm Override
18 Produced IO Size
19 Starter COS Mask
20 Net Out COS Mask
21 DNet Voltage
Grupo de visualización
Parámetros ZIP
101 Output Freq
67 AutoRun Zip
102 Commanded Freq
68 Zone Produced EPR
103 Output Current
69 Zone Produced PIT
104 Output Voltage
70 Zone #1 MacId
105 DC Bus Voltage
71 Zone #2 MacId
106 Drive Status
72 Zone #3 MacId
107 Fault 1 Code
73 Zone #4 MacId
108 Fault 2 Code
74 Zone #1 Health
109 Fault 3 Code
75 Zone #2 Health
110 Process Display
76 Zone #3 Health
112 Control Source
77 Zone #4 Health
113 Contrl In Status
78 Zone #1 Mask
114 Dig In Status
79 Zone #2 Mask
115 Comm Status
80 Zone #3 Mask
116 Control SW Ver
81 Zone #4 Mask
117 Drive Type
82 Zone #1 Offset
118 Elapsed Run Time
83 Zone #2 Offset
119 Testpoint Data
84 Zone #3 Offset
120 Analog In 0...10 V
85 Zone #4 Offset
121 Analog In 4...20 mA
86 Zone #1 EPR
122 Output Power
87 Zone #2 EPR
123 Output Power Fctr
88 Zone #3 EPR
124 Drive Temp
89 Zone #4 EPR
125 Counter Status
90 Zone #1 Control
126 Timer Status
91 Zone #2 Control
127 Timer Stat Fract
92 Zone #3 Control
128 Stp Logic Status
93 Zone #4 Control
129 Torque Current
94 Zone #1 Key
95 Zone #2 Key
96 Zone #3 Key
97 Zone #4 Key
98 Device Value Key
99 Zone Ctrl Enable
Parámetros programables para controladores vectoriales sin sensores Boletín 284
Tabla 6.1
Protección de
DeviceNet
arrancador
22 Breaker Type
23 PrFltResetMode
24 Pr Fault Enable
25 Pr Fault Reset
26 StrtrDN FltState
27 StrtrDN FltValue
28 StrtrDN IdlState
29 StrtrDN IdlValue
61 RAST Pr Fault
62 Warning Status
Configuración
básica
131 Motor NP Volts
132 Motor NP Hertz
133 Motor OL Current
134 Minimum Freq
135 Maximum Freq
136 Start Source
137 Stop Mode
138 Speed Reference
139 Accel Time 1
140 Decel Time 1
141 Reset To Defalts
142 Reservado
143 Motor OL Ret
.
Lista de grupos de parámetros
E/S del usuario
30 Off-to-On Delay
45 Keypad Mode
31 On-to-Off Delay
46 Keypad Disable
32 In Sink/Source
47 Set to Defaults
33 OutA Pr FltState
34 OutA Pr FltValue
35 OutA DN FltState
36 OutA DN FltValue
37 OutA DN IdlState
38 OutA DN IdlValue
39 OutB Pr FltState
40 OutB Pr FltValue
41 OutB DN FltState
42 OutB DN FltValue
43 OutB DN IdlState
44 OutB DN IdlValue
Configuración avanzada
151 Digital In1 Sel
189 Current Limit 1
152 Digital In2 Sel
190 Motor OL Select
153 Digital In3 Sel
191 PWM Frequency
154 Digital In4 Sel
192 Auto Rstrt Tries
155 Relay Out Sel
193 Auto Rstrt Delay
156 Relay Out Level
194 Start At PowerUp
157 Relay Out LevelF
195 Reverse Disable
158 Opto Out1 Sel
196 Flying Start En
159 Opto Out1 Level
197 Compensation
160 Opto Out1 LevelF
198 SW Current Trip
161 Opto Out2 Sel
199 Process Factor
162 Opto Out2 Level
200 Fault Clear
163 DB Threshold
201 Program Lock
164 Opto Out Logic
202 Testpoint Sel
165 Analog Out Sel
203 Comm Data Rate
166 Analog Out High
204 Comm Node Addr
167 Accel Time 2
205 Comm Loss Action
168 Decel Time 2
206 Comm Loss Time
169 Internal Freq
207 Comm Format
170 Preset Freq 0
208 Language
171 Preset Freq 1
209 Anlg Out Setpt
172 Preset Freq 2
210 Anlg In 0...10 V Lo
173 Preset Freq 3
211 Anlg In 0...10 V Hi
174 Preset Freq 4
212 Anlg In 4...20 mA Lo
175 Preset Freq 5
213 Anlg In4...20 mA Hi
176 Preset Freq 6
214 Slip Hertz @ FLA
177 Preset Freq 7
215 Process Time Lo
178 Jog Frequency
216 Process Time Hi
179 Jog Accel/Decel
217 Bus Reg Mode
180 DC Brake Time
218 Current Limit 2
181 DC Brake Level
219 Skip Frequency
182 DB Resistor Sel
220 Skip Freq Band
183 S Curve %
221 Stall Fault Time
184 Boost Select
222 Analog In Loss
185 Start Boost
223 10 V Bipolar Enbl
186 Break Voltage
224 Var PWM Disable
187 Break Frequency
225 Torque Perf Mode
188 Maximum Voltage
226 Motor NP FLA
Misceláneos
DeviceNet de variador
48 Drive Control
49 Drvin PrFltState
50 Drvin PrFltValue
51 Drvin DNFltState
52 Drvin DNFltValue
53 Drvin DNFltState
54 Drvin DNFltValue
55 High Speed Enable
227 Autotune
228 IR Voltage Drop
229 Flux Current Ref
230 PID Trim Hi
231 PID Trim Lo
232 PID Ref Sel
233 PID Feedback Sel
234 PID Prop Gain
235 PID Integ Time
236 PID Diff Rate
237 PID Setpoint
238 PID Deadband
239 PID Preload
240 Stp Logic 0
241 Stp Logic 1
242 Stp Logic 2
243 Stp Logic 3
244 Stp Logic 4
245 Stp Logic 5
246 Stp Logic 6
247 Stp Logic 7
248 Reservado
249 Reservado
250 Stp Logic Time 0
251 Stp Logic Time 1
252 Stp Logic Time 2
253 Stp Logic Time 3
254 Stp Logic Time 4
255 Stp Logic Time 5
256 Stp Logic Time 6
257 Stp Logic Time 7
258 Reservado
259 Reservado
260 EM Brk Off Delay
261 EM Brk On Delay
262 MOP Reset Sel
6-3