2 - Frequency converter
Fault codes
Corresponding
of frequency
faults
controller
Lack of water
E1
Dry running
Sensor is out of
E2
order
E3
Voltage is too low
Voltage is too
E4
high
Current is too
E5
large
E6
Phase loss
E7
Locked-rotor
Communication
E8
failure
IPM is
E9
overheated
E10
Leakage
E11
Flowmeter fault
Temperature
E12
sensor fault
Water
E13
temperature is
too high
Water
E14
temperature is
too low
Fault code of water pump
Fault indicator
The water shortage indicator
(
) is continuously
illuminated.
The water shortage indicator
( ) is flashing.
The pressure sensor
fault indicator (
) is
continuously illuminated.
The voltage (current) fault
indicator ( ) lights up.
The voltage (current) fault
indicator ( ) lights up.
The voltage (current) fault
indicator ( ) is flashing.
The motor fault indicator
(
) lights up.
The motor fault indicator
(
) is flashing.
Er.8 or nothing is displayed
in the LED display area.
E9 is displayed in the LED
display area.
The leakage fault indicator
(
) lights up.
The flowmeter fault indicator
(
) lights up.
The temperature sensor fault
indicator ( ) lights up.
The temperature sensor fault
indicator ( ) is flashing.
The temperature sensor fault
indicator ( ) is flashing.
Solutions
Check whether the water source and
water pressure are sufficient, whether
the air inside pump body is exhausted,
and whether the diameter of inlet pipe is
greater than or equal to that of outlet pipe.
Check whether the pressure sensor lead
wire is normal or replace the pressure
sensor.
Adjust the supply voltage to 0.9~1.1
times of rated value.
Adjust the supply voltage to 0.9~1.1
times of rated value.
Pull out the plug and plug in again.
1. Check whether the three-phase
winding of electric motor is normal.
2. Check whether the lead wire of
frequency converter and electric
motor is open-circuit.
Move the fan to make rotor rotate
flexibly or take apart the pump body to
remove debris.
Open the control box cover, and check
whether the fiat cable between keypad
and control mainboard is plugged firmly.
Check whether the ambient temperature
of water pump is too high.
Please kindly check whether the
pipeline/ pump have leakage problem.
Check whether the flowmeter plug is
plugged firmly or check whether the
turbine of flowmeter is blocked.
Check whether the lead wire of
temperature sensor is normal.
Check whether the water temperature in
the pump body is above 60°C.
Check whether the water temperature in
the pump cavity is below 5°C.
GB