Checking the operators
A- Checking the operators by connecting them directly to the mains supply
The operators can be checked by connecting them
directly to the mains, without using the control panel.
This allows any concerns about operation of the
operator or control panel to be addressed.
Please note the following points:
• Power the operator with the voltage specified in its
characteristics.
• If damaged, replace the capacitor with one with the
same value as specified in the characteristics (230V-
8μF / 125V-25μF).
• The test can be performed with the operator
installed, making sure that the door is in an
intermediate opening/closing position.
M
C
G1
M
G2
COM
T
C
COM
Connections movement 1 (G1):
G1: AC phase (L)
G2: do not connect
COM (grey cable): AC neutral (N)
C: capacitor (230V-8μF / 125V-25μF)
AC
L
G1
G2
N
COM
L
AC
N
G1
L
C
G2
AC
N
MAINTENANCE AND DIAGNOSIS OF FAILURES
SAFETY WARNING: All tests must be performed
by
a
professional
technician who is capable of performing basic
electrical installations, as tampering with
electrical systems poses a significant risk.
Connect the operator as shown in the figure below and
confirm the motor movement in both directions.
Disconnect it once movement has been successfully
checked.
M
G2
C
G1
M
G2
COM
T
C
G1
G2
COM
Connections movement 2 (G2):
G1: do not connect
G2: AC phase (L)
COM (grey cable): AC neutral (N)
C: capacitor (230V-8μF / 125V-25μF)
installer
or
qualified
AC
L
G1
N
COM
L
AC
N
C
L
AC
N
S68A
ARES electro-mechanical operator